Related Experiment Video
Updated: Jan 20, 2026
Combined SPECT and CT Imaging for Cardiac Functionality
Published on: April 30, 2023
The Alpha-SPECT-Mini: A Small-Animal SPECT System based on Hyperspectral Compound-Eye Gamma Cameras
Elena Maria Zannoni1, Can Yang2, Ling Cai2
1Walker Department of Mechanical Engineering at the University of Texas at Austin, Austin, TX 78712 USA and the work described was performed when she was at the Department of Nuclear, Plasma and Radiological Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA.
None:
There is a rising interest in Single Photon Emission Computed Tomography (SPECT) imaging systems with improved energy resolution to facilitate multi-functional molecular imaging applications, such as alpha-emitter radiopharmaceutical therapy (α-RPT). In this paper, we report the design and evaluation of the Alpha-SPECT-Mini system that offers an ultrahigh energy resolution and high sensitivity for small animal studies. The Alpha-SPECT-Mini system is constructed based on small-pixel CdTe detectors that offers sub-1keV Full-Width-Half-Maximum (FWHM) energy resolution for single pixel events and an average ~2.5keV energy resolution at 122 keV and ~3.5 keV at 218 keV over 153600 pixels in the system. This allows to easily identify X- and gamma-ray contributions in densely populated spectra, such as from the Ac-225 decay chain. The system uses a 96-loft-hole collimator and six stationary detection panels in a full ring geometry. Finally, the system performance is demonstrated using Tc-99m- and Ac-225-filled resolution and image quality (IQ) phantoms. We have experimentally demonstrated that the Alpha-SPECT-Mini is a high-performance imaging system capable of imaging alpha-emitters in preclinical applications.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Related Concept Videos
Combined SPECT and CT Imaging to Visualize Cardiac Functionality
Here we will demonstrate the fundamentals of single-photon emission computed tomography/computed tomography (SPECT/CT) imaging using mice. The technique involves injecting a radionuclide into a mouse, imaging the animal after it is distributed throughout the body, and then reconstructing the produced images to create a volumetric dataset. This can...
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
08:34Automated Charting of the Visual Space of Housefly Compound Eyes
07:24Hyperspectral Imaging as a Tool to Study Optical Anisotropy in Lanthanide-Based Molecular Single Crystals
Evaluating the Neuroprotective Effects of a Test Compound Against Alpha-Synuclein Toxicity in Rat Embryonic Neurons