Related Experiment Video
Updated: Jan 20, 2026

Arterial Pouch Microsurgical Bifurcation Aneurysm Model in the Rabbit
Published on: May 14, 2020
Flow-Diversion Device Implantation for Combined Intracranial Dissecting Aneurysm and Vertebral Artery Dissection
1Department of Neurosurgery, The Second Clinical Medical College of Jinan University, Shenzhen People's Hospital, Shenzhen, Guangdong, China.
Abstract:
Over the past decade, flow-diversion devices (FDD) have emerged as a novel treatment modality for intracranial aneurysms. To address the need for safer application of FDD in more complex scenarios (such as tortuous, distal, overlapping, or multiple aneurysms), we report a case of FDD placement in a 49-year-old patient with an intracranial artery dissection complicated by vertebral artery dissection. This demonstrates the safety and efficacy of FDD in treating complex intracranial artery lesions.
Related Concept Videos
06:11Arterial Pouch Microsurgical Bifurcation Aneurysm Model in the Rabbit
06:31Identification and Dissection of Diverse Mouse Adipose Depots
04:08Fluorescence Angiography for Evaluation of Aneurysm Perfusion and Parent Artery Patency in Rat and Rabbit Aneurysm Models
08:21High-Dimensionality Flow Cytometry for Immune Function Analysis of Dissected Implant Tissues
18:50Microsurgical Clip Obliteration of Middle Cerebral Aneurysm Using Intraoperative Flow Assessment
07:21Microsurgical Creation of Giant Bifurcation Aneurysms in Rabbits for the Evaluation of Endovascular Devices