Cost-Effective and User-Friendly Pencil Graphite Electrode Immunosensor for Label-Free Detection of Carcinoembryonic
Sevda Akay Sazaklioglu1, Hüseyin Çelikkan2
1Ankara Medipol University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Turkey.
None:
We present a novel, cost-effective sensor for carcinoembryonic antigen (CEA) detection utilizing a pencil graphite electrode (PGE) in combination with electrochemical impedance spectroscopy (EIS), which offers high sensitivity and selectivity. Anti-CEA/AuNPs/PGE was successfully illustrated as a label-free impedimetric immunosensor for the detection of CEA. Through EIS, we observed distinct impedance changes upon CEA binding, enabling real-time detection with high reproducibility and low interference from non-target molecules. Due to its satisfying impedimetric response, this new immunosensor demonstrated that it can be used for high-performance detection of CEA with a wide linear range extending from 13.2 to 1 × 105 pg mL-1, with correlation coefficients (R2) of 0.9923. The PGE's excellent conductive properties and surface stability allowed for the successful detection of CEA at low concentrations, demonstrating a detection limit of 4.4 pg mL-1, which is competitive with existing, more costly alternatives. The sensor's robust performance in spiked artificial urine samples indicates its potential for practical application in point-of-care cancer diagnostics, especially in resource-limited environments. The developed electrochemical biosensor holds promise for accurately detecting CEA in urine samples, offering a precise technique that could find valuable application in clinical tumor detection.
More Related Videos
08:27Detection of Human Leukocyte Antigen Biomarkers in Breast Cancer Utilizing Label-free Biosensor Technology
Published on: March 24, 2015
08:39High-throughput Image Analysis of Tumor Spheroids: A User-friendly Software Application to Measure the Size of Spheroids Automatically and Accurately
Published on: July 8, 2014
Related Concept Videos
Framing Effects
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Standard Electrode Potentials
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Antigen Presenting Cells
T cells require the help of antigen-presenting cells (APCs), which process foreign antigens into smaller fragments that can be recognized by T cells. These APCs are highly specialized cells that efficiently internalize antigens...
Biological Effects of Radiation