Squeeze-and-Excitation Enhanced Convolutional Neural Networks for Multi-class Pneumonia Classification on Chest
Kian A Huang1, Haris K Choudhary1, Ashley Santiago1
1Radiology, University of South Florida Morsani College of Medicine, Tampa, USA.
Abstract:
This study compared two convolutional neural network (CNN) architectures, ResNet50V2 and InceptionV3, each enhanced with squeeze-and-excitation (SE) attention mechanisms, for automated classification of chest X-rays into normal, pneumonia-bacterial, pneumonia-viral, and COVID-19 categories. A total of 9,208 posterior-anterior chest radiographs were analyzed, divided into training, validation, and test datasets under identical preprocessing and fine-tuning conditions. ResNet50V2-SE achieved a test accuracy of 98.18% and a macro-averaged area under the curve (AUC) of 0.9951, while InceptionV3-SE achieved 97.86% accuracy and an AUC of 0.9949. Class-specific evaluation showed that ResNet50V2-SE classified normal radiographs with perfect precision, recall, and F1-score (1.00). Pneumonia-bacterial images were classified with a precision, recall, and F1-score of 0.99, while pneumonia-viral and COVID-19 images reached F1-scores of 0.98 and 0.95, respectively. Comparable results were observed with InceptionV3-SE, achieving F1-scores of 1.00 for normal, 0.99 for pneumonia-bacterial, 0.97 for pneumonia-viral, and 0.95 for COVID-19. McNemar's test was performed to compare model performance on the same test set. ResNet50V2-SE was correct in eight cases where InceptionV3-SE was incorrect, whereas InceptionV3-SE was correct in two cases where ResNet50V2-SE was incorrect. The resulting χ² statistic was 0.1250 (p>0.05), indicating no statistically significant difference in classification performance between the two models. Both SE-enhanced CNN architectures demonstrated high accuracy and generalizability for differentiating among pneumonia subtypes on chest X-rays. These findings suggest that attention-augmented deep learning models may serve as effective decision-support tools in radiologic diagnosis, warranting further validation across larger and more diverse clinical datasets.
Related Concept Videos
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Flail Chest-I
Flail chest is a severe and potentially life-threatening condition characterized by the fracture of three or more adjacent ribs in multiple places. It is most commonly caused by direct impacts and trauma, such as motor vehicle accidents or injuries from a steering wheel impact. It can also occur due to falls in elderly individuals with osteoporosis, or assaults involving sharp objects.
Pathophysiology
The pathophysiology of flail chest is complex, involving fractures of...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...
Convolution Properties I
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output:
Pneumonia I: Introduction
Risk Factors
Various factors influence the likelihood of developing pneumonia. Age plays a crucial role, with infants, children under two, and individuals over 65 at increased risk due to their...