Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Rapid optimization of focused ultrasound for complex targeting with phased array transducers and precomputed
Maximilian Valentin Hasslberger1,2, Mathew George Abraham1,3, Kasra Naftchi-Ardebili4
1Department of Radiology, Stanford University, Stanford, CA 94305, United States of America.
None:
Objective. Low-intensity focused ultrasound has emerged as a versatile tool for various applications including noninvasive neuromodulation and blood-brain barrier (BBB) opening. To achieve precise individual targeting, phase aberration correction (PAC) is essential to compensate for the heterogeneities introduced by the skull. Traditional methods for PAC are restricted to single point-based targets, resulting in elongated, cigar-shaped focal beams that often fail to align with the geometry of the intended target. Additionally, these approaches demand lengthy simulation times, making the simultaneous sonication of multiple targets within a reasonable timeframe infeasible.Approach. This work introduces rapid optimization-based sonication of volumetric brain targets. By leveraging a pair of linear phased array transducers aligned orthogonally above the skull, the approach is capable of optimizing phase and amplitude parameters within seconds to focus acoustic pressure at multiple targets inside target volumes while limiting potential off-target activation.Main results. Three brain areas were targeted under different orthogonal transducer alignments, enforcing the desired intracranial peak pressure at a minimum of three target points in each region. Further results demonstrate the sensitivity of transducer displacements, particularly with translational and rotational misalignments. A ray tracing correction scheme was employed, restoring the peak pressure at the intended target region while keeping the increase in off-target pressure below 20%.Significance. Overall, these advancements hold promise for enhancing targeting in focused ultrasound-guided BBB opening and neuromodulatory applications, expanding the utility of ultrasound in clinical and experimental settings.
More Related Videos
Related Concept Videos
Phase Transitions
Propagation of Waves
Consider a scenario where a wave propagates from a string of low linear mass density to a string of high linear mass density. In such a case, the reflected wave is out of phase with respect to the incident wave, however the...
Phase Diagrams
Propagation of Action Potentials
Neurons (nerve cells) have a resting membrane potential, with a slightly negative charge inside compared to outside. This is maintained by ion channels, such as sodium (Na+) and potassium (K+) channels, which control the flow of ions. When a stimulus, like a touch or a signal from another neuron, triggers the neuron, sodium channels open, allowing sodium ions to...
Protein Complexes with Interchangeable Parts
The SCF ubiquitin ligase is a protein complex of five individual proteins. This complex attaches ubiquitin to other target proteins to mark them for degradation. In order...
Operational Amplifiers