Safety profile of long-term intraocular ophthalmic viscoelastic devices: a systematic review
Rana Khalil1, Diya Shah2, Aman Sutaria2
1Tennent Institute of Ophthalmology, Glasgow, UK rana.khalil@nhs.scot.
Purpose:
Since first being introduced over 50 years ago, ophthalmic viscoelastic devices (OVDs) have revolutionised the fields of cataract, cornea and glaucoma surgery, with extensive published anterior segment safety data available. More recently, these devices have also gained popularity in posterior segment surgery, with particular focus on their potential use as long-lasting, non-toxic, biocompatible and biodegradable vitreous substitutes. The most commercially available products are based on hydrophilic polymers such as hyaluronic acid (HA), hydroxypropylmethylcellulose (HPMC) and chondroitin sulfate (CS). This remains a novel area of research, with very few studies examining their long-term safety profile.
Methods:
We conducted a systematic review on Medline and Embase via OVID, using key words "viscoelastics" and "intraocular". Both databases were searched from inception date, with no language limitations.
Results:
There is a paucity of high-quality evidence addressing the long-term safety of OVDs in the eye. A total of 38 studies were included for final review. These studies were unsuitable for any direct head-to-head comparisons; therefore, a descriptive analysis is presented.
Conclusions:
By far, HA-based OVDs have been the most well described, with several long-term intraocular applications. They display highly favourable biophysical properties with minimal adverse reactions in short and long-term in vivo, in vitro and animal studies. There is limited safety data on HPMC and CS-based products, despite their popularity. This represents a gap in the literature and invites the need for high-quality evidence to support their continued use, particularly in the realms of vitreoretinal surgery and chronic hypotony.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Survey Safety
Random and Systematic Errors
Systematic Sampling Method
Systematic sampling is one of the simplest methods...
Long-term Depression