Related Experiment Video
Updated: Jan 22, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Evolution of the Aorta After Valve Replacement in Bicuspid Aortic Valves: Results at Mid-Term Follow-Up
Raffaele Giordano1, Shadi Hamameh1, Vincenzo Speranza1
1Department of Advanced Biomedical Sciences, Division of Cardiac Surgery, Federico II University, Naples, Italy.
Aim:
Bicuspid aortic valve (BAV) is a common congenital heart defect often associated with ascending aorta dilation. Current guidelines suggest surgical intervention for diameters ≥45 mm in conjunction with surgical aortic valve replacement (SAVR). However, the optimal management of ascending aortas measuring 40-44 mm remains under debate. This study aims to evaluate the evolution of aortic diameter in patients with BAV and ascending aorta diameters between 40 and 44 mm undergoing aortic valve replacement, assessing whether a conservative approach is justified.
Method:
We conducted a retrospective observational study, analysing 88 patients with BAV who underwent SAVR between January 2012 and December 2018. Patients were divided into two groups based on preoperative ascending aorta diameters: <40 mm (Group 1, n=15) and the ≥40 and <45 mm (Group 2, n=11). Follow-up of at least 5 years included aortic dilation rates, survival, and reoperation rates.
Results:
No significant differences were observed in aortic dilation between the two groups during follow-up, with overall annual dilation rates of 0.2±0.07 mm/year. Survival rates were 86.3% for Group 1 and 81.9% for Group 2, with no reoperations required in either group.
Conclusions:
Patients with BAV and ascending aorta diameters of 40-44 mm do not require prophylactic aortic replacement during AVR, provided they undergo regular follow-up. These findings support current guidelines advocating conservative management for ascending aorta diameters in this range. However, in younger patients or those nearing the 45 mm threshold, surgical replacement may still be considered to pre-empt future complications.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
The Evidence for Evolution
Anatomy of the Heart