Use of Magnetic Resonance Imaging and Biopsy Data to Guide Sampling Procedures for Prostate Cancer Biobanking
Published on: October 10, 2019
5 T versus 3 T MRI for prostate cancer: an intra-individual prospective comparison of image quality and diagnostic
Tianyu Xiong1,2, Liting Shen3, Yunpeng Fan1,2
1Department of Urology, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China.
Background:
To prospectively compare the image quality and diagnostic performance of ultra-high-field 5 T MRI with that of standard 3 T in patients with suspected prostate cancer (PCa).
Methods:
Sixty-seven consecutive patients received prostate scan at both 5 T and 3 T MRI systems. Two radiologists independently evaluated the images in a double-blind manner. A head-to-head comparison of 5 T and 3 T MRI was conducted from both qualitative and quantitative perspectives. Pathological results from prostate biopsy and radical prostatectomy were used as the gold standard to evaluate the diagnostic performance.
Results:
5 T MRI demonstrated superior image quality and enhanced visualization of prostatic anatomical structures, including prostatic capsule, seminal vesicle and neurovascular bundles. The lesion delineation was significantly improved in 5 T MRI. The elevated field strength resulted in a significantly higher signal-to-noise ratio, contrast-to-noise ratio, edge rise distance and lesion slope profile in both T2WI and DWI sequences without introducing additional artifacts. Moreover, 5 T MRI demonstrated improved diagnostic performance for biopsy outcomes and pathological features than 3 T.
Conclusion:
5 T MRI effectively improves PCa assessment compared to 3 T. Our study provides preliminary evidence for the feasibility of 5 T MRI in PCa diagnosis and evaluation.
Related Concept Videos
Chemotherapy-Induced Nausea and Vomiting: 5-HT3 Receptor Antagonists
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Impact of Individuals on Individuals
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...