Related Experiment Video
Updated: Jan 22, 2026

Echocardiographic Characterization of Left Ventricular Structure, Function, and Coronary Flow in Neonate Mice
Published on: April 7, 2022
Comparison of 3-dimensional echocardiographic left ventricular volume assessment from different acoustic windows
1Department of Cardiology, Ajou University School of Medicine, Suwon, Korea.
Abstract:
Three-dimensional echocardiography (3DE) has been reported to be accurate and precise in left ventricular (LV) volume assessment. We validated the accuracy of 3DE for quantifying LV volume acquired from various different acoustic windows. Twenty patients with good acoustic windows were enrolled. The 3DE images were acquired from the point of maximal intensity (PMI) (A, apical 4-chamber view), the point of 1 intercostal space above from the PMI (B), the point of medial side of PMI with angling probe laterally, toward the patients' left shoulder (C, right ventricular modified 4-chamber view) and the point of 4th intercostal space of midclavicular line (D). The measurements of LV volume at end diastole and end systole by 3DE acquired from 4 different acoustic windows were done offline and analyzed. We set the LV volume quantified from image of apical 4-chamber view as the standard LV volume. Linear association between the methods was measured with simple linear regression analysis and with Pearson correlation coefficient. Bland-Altman plot was created to calculate the limits of agreement. The end diastolic and end systolic LV volumes measured from apical 4-chamber view ranged from 45.7 to 105.5 mL and from 17 to 35.5 mL. Using simple linear regression analysis and Bland-Altman plot analysis, both the end diastolic and end systolic LV volumes measured from each image acquired from each positions showed high agreement. Using the semi-automated analysis tool of the QLAB Advanced Ultrasound Quantification Software Release 8.1, the maximal time required for the volume measurement of images from A, B, C and D were 180, 208, 248 and 359 seconds, respectively. Our results demonstrated the feasibility and accuracy of 3DE for clinical assessment of LV volume irrespective of any acoustic windows.
More Related Videos
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Molecular Comparison of Gases, Liquids, and Solids
Constant Volume Calorimetry
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Work Done During Volume Change
Consider a gas confined to a cylinder fitted with a movable piston at one end. If the gas expands from volume V1 to volume V2, it exerts a force on the piston, such that the piston moves by a distance dr.
The work done by the gas on the piston can be expressed as