Related Experiment Video
Updated: Jan 22, 2026

High Frequency Ultrasound for the Analysis of Fetal and Placental Development In Vivo
Published on: November 8, 2018
Sylvian fissure angle development on fetal MRI: 22-38 gestational weeks
Yan Song1, Siyan Lu1, Hongyu Yin1
1Department of Radiology, Sichuan Provincial Woman's and Children's Hospital, The Affiliated Women's and Children's Hospital of Chengdu Medical College, Chengdu, Sichuan, China.
Objective:
The objective of the study was to quantify Sylvian fissure angle (SFA) development via fetal magnetic resonance imaging (MRI) and establish the reference range and growth curve during normal pregnancy.
Materials And Methods:
This retrospective cross-sectional study collected 324 singleton fetuses at 22-38 weeks of gestation (GA), without abnormal signs on MRI or chromosomal defects, from January 2022 to December 2023. Six SFAs were defined and measured: Sylvian fissure plateau angle (SFPA), Sylvian fissure anterior rotation angle (SFARA), and Sylvian fissure posterior rotation angle (SFPRA) in the transthalamic axial plane, and SFPA, Sylvian fissure superior rotation angle (SFSRA), and Sylvian fissure inferior rotation angle (SFIRA) in the third ventricular coronal plane. Then, the correlation between the SFAs and GA was analyzed, and the growth curve model was used. Retrospective cortical malformation cases validated the model. The intraclass correlation coefficient (ICC) was used to evaluate interobserver variability of the SFA measurements.
Results:
ICC for SFA measurements demonstrated good reliability (0.772-0.976). The bilateral SFARA and SFSRA were significantly positively associated with GA (r = 0.914, 0.926, 0.842, 0.836, left to right, all p < 0.001). The bilateral SFPRA, SFIRA, and SFPA (both axial and coronal views) were negatively associated with GA (r value range: -0.601 to -0.145, all p < 0.001). For each SFA and GA, the quadratic curve has the best goodness of fit. The model detected cortical malformation (genetically confirmed). Except for the SFARA, all SFAs were statistically different between the two sides.
Conclusion:
The dynamic development of the fetal SFA can be well evaluated using MRI. The SFA's reference range will enhance the accuracy of fetal brain assessment and offer a quantitative reference framework for identifying deviations suggestive of cortical malformations.
More Related Videos
Related Concept Videos
Diabetes Mellitus: Type 2 and Gestational
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle of Twist: Problem Solving
Angle Closure Glaucoma: Treatment

