Comparative Analysis of Robotic Assistive Devices on Paretic Knee Motion in Post-Stroke Patients: An IMU-Based Pilot
Toshiaki Tanaka1,2, Shunichi Sugihara3, Takahiro Miura4
1Research Center for Advanced Science and Technology (RCAST), The University of Tokyo, Tokyo 113-8656, Japan.
Abstract:
Background: Robotic assistive devices are increasingly used in post-stroke gait rehabilitation, yet quantitative evaluations of synchronization between human and robotic joint motion remain limited. This study examined gait kinematics in post-stroke hemiplegic patients using two exoskeleton-type devices-HAL® (Cyberdine Inc., Tsukuba, Japan) and curara® (AssistMotion Inc., Ueda, Japan)-based on synchronized IMU measurements. Methods: Two post-stroke patients performed treadmill walking under non-assisted and assisted conditions with HAL® and curara®. Only the paretic knee joint was analyzed to focus on the primary control joint during gait. Inertial measurement units (IMUs) simultaneously recorded human and robotic joint angles. Synchronization was assessed using Bland-Altman (BA) analysis, root mean square error (RMSE), and mean synchronization jerk (MSJ). The study was designed as an exploratory methodological case study to verify the feasibility of synchronized IMU-based human-robot joint measurement. Results: Both assistive devices improved paretic knee motion during gait. RMSE decreased from 7.8° to 4.6° in patient A and from 8.1° to 5.0° in patient B. MSJ was lower during curara-assisted gait than HAL-assisted gait, indicating smoother temporal coordination. BA plots revealed reduced bias and narrower limits of agreement in assisted conditions, particularly for curara®. Differences between HAL® and curara® reflected their distinct control strategies-voluntary EMG-based assist vs. cooperative gait-synchronization-rather than superiority of one device. Conclusions: Both devices enhanced synchronization and smoothness of paretic knee motion. curara® demonstrated particularly smooth torque control and consistent alignment with human movement. IMU-based analysis proved effective for quantifying human-robot synchronization and offers a practical framework for optimizing robotic gait rehabilitation. The novelty of this study lies in the direct IMU-based comparison of human and robotic knee joint motion under two contrasting assistive control strategies.
More Related Videos
Related Concept Videos
Comparing the Survival Analysis of Two or More Groups
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Pilot and Numeric Relaying
Relative Motion Analysis - Acceleration
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...