Pulsed-Field Ablation to Enhance the Durability of Pulmonary Vein Isolation and Treat Paroxysmal Atrial Fibrillation
Vivek Y Reddy1, Hans Kottkamp2, Hugh Calkins3
1Helmsley Electrophysiology Center, Mount Sinai Fuster Heart Hospital, New York, New York, USA.
Background:
In first-in-human studies of the treatment of paroxysmal atrial fibrillation (PAF), a multielectrode globular spherical array pulsed field ablation (PFA) catheter and system able to map, pace, sense contact, and ablate exhibited a high rate, 94%, of durable pulmonary vein isolation (PVI).
Objectives:
In this study, the authors sought to assess the 1-year outcomes of a multicenter single-arm pivotal trial of the spherical array system to treat PAF.
Methods:
In the multicenter PULSAR pivotal investigational device exemption trial, patients with symptomatic drug-resistant or intolerant PAF underwent PVI with the use of the spherical array system. The array catheter was used to render left atrial anatomy and voltage and perform PVI. The primary effectiveness endpoint was a composite of 12-month freedom from atrial arrhythmias (as assessed by weekly and symptomatic transtelephonic monitoring and 24-hour Holter monitoring) and freedom from other failure modes: failure to achieve PVI, repeated ablation or cardioversion, and the use of new or increased doses of class I or III antiarrhythmic drugs. The primary safety endpoint included primary adverse events within 7 days of the index ablation procedure.
Results:
The study cohort of 183 patients included 19 roll-in and 164 pivotal patients: aged 65 ± 9.1 years, 40% female, CHA2DS2-VASc 2.1 ± 1.4, left atrial diameter 3.8 ± 0.6 cm. Mapping time (9.0 ± 5.5 min), transpired ablation time (25.6 ± 9.8 min), left atrial catheter dwell time (59.9 ± 11.6 min), and procedure time (95.8 ± 20.7 min) revealed an efficient procedure. Most pulmonary veins (PVs) (94%, 607/647 veins) were electrically isolated by the first pulsed field application. The primary safety event rate was 0.6% (1/164): a hemorrhagic stroke identified immediately after the procedure in a patient with severe hypertension and polycystic kidney disease. The PV stenosis substudy revealed no patients with moderate or severe vein narrowing. Primary effectiveness at 12 months was 77.8% (95% CI: 70.6%-83.9%). During redo ablation in 11 patients, 39 of 41 (95.1%) pulmonary veins remained durably isolated.
Conclusions:
The favorable clinical success observed in this multicenter Food and Drug Administration trial of this novel PFA catheter appears to reflect the clinical success achievable with durable PVI in PAF patients. (Safety and Effectiveness of the Globe Pulsed Field System for Treating Patients with Symptomatic Paroxysmal or Persistent Atrial Fibrillation [PULSAR]; NCT05462145).
More Related Videos
11:03Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Brick Durability, Strength, and Appearance
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...