Related Experiment Video
Updated: Jan 23, 2026

Toxicity Study of Zinc Oxide Nanoparticles in Cell Culture and in Drosophila melanogaster
Published on: September 19, 2019
Deciphering copper and zinc leaching from antifouling paints with different operating modes: flux determination and
V Lenoble1, N Layglon2, C Pages1
1Univ Toulon, Aix Marseille Univ., CNRS/INSU, IRD, MIO UM 110, Mediterranean Institute of Oceanography, La Garde, France.
Abstract:
Laboratory experiments were performed using 3 antifouling paints with different operating modes immersed in seawater for 7 days, to estimate copper and zinc fluxes and determine the scale of the related contamination. The toxicity of antifouling paints leachates was also assessed for natural bacterioplanktonic and phytoplanktonic communities. Given the increase in copper and zinc concentrations (4 to 1750-fold enrichment in dissolved Cu and to 7 to 200-fold enrichment in dissolved Zn), a systematic mortality upon phytoplankton was evidenced within 2 days of exposure to leachates produced from 1 h to 2 days of immersion, whatever the paint. This went oppositely with the environmental risks calculated according to European guidelines, demonstrating an acceptable risk for the environment. Considering that 1 h of leaching from a 7 cm2 painted disk polluted 0.5 L of seawater with Cu in our experimental conditions whatever the paint used, we estimated that a painted ship hull of 15 m2 can pollute more than 10 m3 of seawater within the same time. Leachates produced after only 20 min even yielded phytoplankton growth inhibition or mortality for insoluble and self-polishing paints, respectively, shortening the time needed for a freshly painted ship hull of 15 m2 to pollute 10 m3. The bacterioplanktonic community appeared less sensitive than phytoplankton but demonstrated the same hierarchy: the highest toxicity was observed for the insoluble matrix and the lowest toxicity for the soluble one. This study therefore brings added value in terms of biocides flux determination, range of studied paints and concrete toxicity evaluation.
Related Concept Videos
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...
The Evidence for Evolution
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Electric Flux
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Magnetic Flux
Suppose a surface is divided into elements of area dA. For each element, the component of the magnetic field that is normal to the...