Related Experiment Video
Updated: Jan 23, 2026

Author Spotlight: Innovative Methodology for Implanting and Securing Neural Probes in the Rodent Spinal Cord
Published on: July 12, 2024
Device-Removal, Reinfection, and Mortality After Staphylococcus aureus Bacteremia in Patients With Cardiac
Kasper Høtoft Bengtsen1, Melanie Vuong Le1, Ketil Haugan1
1Department of Cardiology, Zealand University Hospital, Roskilde, Denmark.
Background:
In case of Staphylococcus aureus bacteremia (SAB), complete cardiac implantable electronic device (CIED) removal is advised by the European Heart Rhythm Association.
Objectives:
The objective of the study was to estimate clinical outcomes after SAB in the Danish CIED carriers.
Methods:
We conducted a nationwide register-based cohort study including all patients with SAB after CIED implantation between 2000 and 2020. Cumulative incidence of device removal, SAB reinfection, and all-cause mortality were estimated and compared to sex and age-matched non-CIED controls with SAB. Landmark analysis at the time of hospital discharge estimating mortality and reinfection according to CIED removal status in surviving patients was conducted.
Results:
In total, 1,816 patients with CIED and SAB and 9,080 matched controls were included in the study (median age 77.5 years, 73.0% males). Thirty-day all-cause mortality was 34.0% (95% CI: 31.8%-36.2%) in patients with CIED and 31.0% (95% CI: 30.0%-31.9%) in controls (P = 0.019, adjusted HR: 1.11 [95% CI: 1.02-1.22]). Device removal within 30 days was performed in 286 patients (15.8%). The landmark analysis showed significantly lower 180-days cumulative incidence of SAB reinfection and all-cause mortality in patients undergoing device removal compared to those with retained CIEDs (reinfection: 2.5% vs 5.5%; mortality: 7.8% vs 31.2%). Patients who underwent CIED removal were younger and had less comorbidity compared to those with retained CIEDs.
Conclusions:
The Danish CIED carriers had slightly higher 30-day all-cause mortality after SAB compared to matched controls. Only a minor selected proportion underwent device removal after SAB diagnosis and, after initial survival, these patients had lower 180-days reinfection rates and mortality compared to patients with retained devices.
Related Concept Videos
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Electron Affinity
Electron Behavior
Electrons are negatively charged subatomic particles that are attracted to an orbit around the positively-charged nucleus of an atom. They reside in locations that are associated with energy levels called shells and are further organized into sub-shells and orbitals within each shell.
Electrons Orbit the Nucleus
Electrons are found in specific locations outside of the nucleus. The shell in which an electron resides indicates the general energy level of the electron: those closer to the...

