Fully automated frame selection and region-of-interest placement in 2D shear wave elastography: reduced examination
Hyo-Jin Kang1,2, Jeong Hee Yoon1,2, Jeong Min Lee1,2
1Department of Radiology, Seoul National University Hospital, Seoul, Korea.
Purpose:
This study evaluated the clinical utility of a fully automated two-dimensional shear wave elastography (2D-SWE) method incorporating automated frame selection and region-of-interest (ROI) placement algorithms in participants with diffuse liver disease. The analysis assessed examination time and reproducibility compared with semi-automated and manual methods.
Methods:
This prospective study included 40 participants who underwent liver stiffness measurements with a Samsung Medison ultrasound system using three.
Methods:
fully automated (automated frame selection via a reliability indicator derived from elasticity uniformity and the reliability measurement index, with automated ROI placement); semi-automated (automated frame selection with manual ROI placement); and manual (fully operator-controlled). Examination time and inter-method (n=40), intra-observer (n=21), and inter-observer (n=15) variabilities were analyzed using analysis of variance, paired t-tests, and intraclass correlation coefficients (ICCs). All participants underwent comparative measurements with a Canon i800 system for cross-platform analysis.
Results:
One technical failure each occurred during the intra-observer and cross-platform measurement sessions. Fully automated measurement significantly reduced total examination time (14.38±5.01 seconds) compared to semi-automated (30.46±7.11 seconds, P<0.001) and manual (33.05±7.10 seconds, P<0.001) measurements. No significant differences in liver stiffness were observed among methods (P=0.556). Inter-method agreement was excellent (ICC, 0.997). Intra-observer and inter-observer agreements were also excellent with the fully automated method (ICCs, 0.971 and 0.984, respectively). Good cross-platform agreement with the Canon system was observed (ICC, 0.833).
Conclusion:
Fully automated 2D-SWE markedly reduces examination time while maintaining high reproducibility in liver stiffness assessment.
More Related Videos
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
11:24Evaporation-reducing Culture Condition Increases the Reproducibility of Multicellular Spheroid Formation in Microtiter Plates
Published on: March 7, 2017
Related Concept Videos
Framing Effects
Diseases of the Liver and Gallbladder
Cirrhosis is characterized by the scarring of hepatic lobules in the liver, which are replaced by fibrous tissue, affecting the liver's normal functioning. NAFLD, on the other hand, is caused by an excessive build-up of fat in the liver, not...
Frames
Frames are versatile and widely used in various applications such as structural supports for beams and columns, automobile chassis construction, and in the construction...
Diffusion
Frames: Problem Solving I
Frames: Problem Solving II