Sparse Sonomyography-based Estimation of Isometric Force: A Comparison of Methods and Features
Anne Tryphosa Kamatham1, Meena Alzamani2, Allison Dockum2
1Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi 110016 India.
Abstract:
Noninvasive methods for estimation of joint and muscle forces have widespread clinical and research applications. Surface electromyography (sEMG) provides a measure of the neural activation of muscles which can be used to estimate the force produced by the muscle. However, sEMG based measures of force suffer from poor signal-to-noise ratio and limited spatiotemporal specificity. In this paper, we propose a sonomyography or ultrasound imaging-based offline approach for estimating continuous isometric force from a sparse set of ultrasound scanlines. Our approach isolates anatomically relevant features from A-mode scanlines isolated from B-mode images, thus greatly reducing the dimensionality of the feature space and the computational complexity involved in traditional ultrasound-based methods. We evaluate the performance of four regression methodologies for force prediction using the reduced sonomyographic feature set. We also evaluate the feasibility of a practical wearable sonomyography-based system by simulating the effect of transducer placement and varying the number of transducers used in force prediction. Our results demonstrate that Gaussian process regression models outperform other regression methods in predicting continuous force levels from just four equispaced transducers in offline settings. We believe that these findings will aid in the design of wearable, robust and computationally efficient sonomyography-based force prediction systems.
More Related Videos
Related Concept Videos
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Intermolecular Forces
Isotonic and Isometric Muscle Contractions
Isotonic contractions
Isotonic contractions occur when a muscle changes length while...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...