Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Comparing Clinical Outcomes of Patients With a Small Versus Large Annulus After Newer-Generation Balloon-Expandable
Kazuki Suruga1, Vivek Patel1, Takashi Nagasaka1,2
1Cedars-Sinai Medical Center Smidt Heart Institute Los Angeles CA.
Background:
Limited data are available comparing clinical outcomes between patients with small and large annuli following transcatheter aortic valve replacement using balloon-expandable valves. This study sought to investigate 5-year clinical outcomes in patients with severe aortic stenosis with a small annulus compared with those with a large annulus following transcatheter aortic valve replacement with newer-generation balloon-expandable valves.
Methods:
A total of 3182 patients with aortic stenosis treated with balloon-expandable valves were divided into small-annulus (≤430 mm2) and large-annulus (>430 mm2) groups. A 1:1 propensity-matched analysis was performed to adjust baseline differences. The primary end point was all-cause death at 5-year follow-up. Secondary end points included heart failure hospitalization, bioprosthetic valve failure, and aortic valve reintervention.
Results:
Among 533 matched pairs, compared with the large-annulus group, the small-annulus group had higher rates of aortic valve mean gradients ≥20 mm Hg (14.1% versus 2.9%; P<0.001) and severe prosthesis-patient mismatch (9.8% versus 5.2%; P=0.019). At 5 years, there were no significant differences in all-cause death (hazard ratio, 0.75 [95% CI, 0.52-1.09]; P=0.13). The incidence of heart failure rehospitalization, bioprosthetic valve failure, and aortic valve reintervention were similar between groups. Both groups achieved similar sustained improvements in New York Heart Association functional class and Kansas City Cardiomyopathy Questionnaire-Overall Summary scores.
Conclusions:
Despite higher transvalvular gradients and a greater rate of severe prosthesis-patient mismatch, 5-year clinical outcomes in patients with a small annulus were comparable to those with a large annulus following transcatheter aortic valve replacement using newer-generation balloon-expandable valves.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Predicting Reaction Outcomes
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Continuous Renal Replacement Therapy
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care...