1Department of Radiology, Children's Hospital of Chongqing Medical University, National Clinical Research Center for Children and Adolescents' Health and Diseases, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Structural Birth Defect and Reconstruction, No.136 Zhongshan 2 Road, Yuzhong District, 400014, Chongqing, China.
Background:
While single-energy hand computed tomography angiography (CTA) often yields suboptimal visualization of distal vessels, dual-energy computed tomography (CT) with low-keV virtual monoenergetic image (VMI) reconstruction enhances small-vessel conspicuity.
Objective:
To evaluate the value of dual-energy CT VMIs in pediatric hand CTA.
Materials And Methods:
This retrospective study included 49 pediatric patients. Seven image series per patient were generated from dual-energy data: an M_0.5 image (50% 70 kVp+50% tin-filtered 150 kVp), a 70-kVp image, and five VMIs at 40-80 keV (10-keV increments). Objective metrics (attenuation, vessel noise, signal-to-noise ratio, contrast-to-noise ratio) and subjective scores were assessed for five vessels: the radial artery, the ulnar artery, the common palmar digital artery, and the proximal and distal parts of the proper palmar digital artery. Subjective image quality was independently evaluated by two radiologists using a 4-point Likert scale.
Results:
The 40-keV VMIs provided the highest vascular attenuation across all vessels, albeit with the highest noise. Subjective scores for the radial, ulnar, and common palmar digital arteries showed no significant differences among the 40-keV, 50-keV, and 70-kVp series. However, for the small distal proper palmar digital arteries and total image quality, the 40-keV series was rated superior to the other series. No significant differences in image quality existed between the 70-kVp and 50-keV images.
Conclusion:
For pediatric hand CTA, 40-keV VMIs provide optimal vascular conspicuity for small distal vessels, yielding the highest diagnostic confidence and total image quality score, and this benefit outweighs the associated increase in vessel noise.
More Related Videos
06:53Creating Virtual-hand and Virtual-face Illusions to Investigate Self-representation
Published on: March 1, 2017
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Conservation of Energy: Application
Application of the Energy Equation
Energy Basics
What is Energy?