Integrated Diagnosis and Therapy Using Flexible Contact Electrodes: Low-Voltage Irreversible Electroporation and
Yuchen Cheng1,2, Bowang Cheng1,2, Jingyu Li3
1State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, 710049, Shaanxi, China.
Abstract:
Irreversible electroporation (IRE) is a minimally invasive, non-thermal, and cell-selective technique. When combined with the noninvasive nature of contact electrodes, they hold great promise for the treatment of cardiac conditions, gastrointestinal tumors, and superficial lesions. However, its broader clinical application is hindered by its reliance on a kilovolt-level, high-voltage pulse characteristics power supply and the lack of real-time postoperative assessment methods for evaluating ablation efficacy. To address these challenges, a contact electrode system with integrated IRE and impedance monitoring functions was developed. Numerical simulations were performed to optimize the anode, gap, and cathode widths in the concentric electrode design. This ensured efficient electric-field focusing under low-voltage conditions. The ablation performance was verified using a potato model. A four-electrode impedance measurement technique was used to capture the spectral characteristics of biological tissues. The impedance changes were analyzed using a double-shell equivalent circuit model. The system achieved a 2 mm ablation depth at 125 V, which is suitable for the treatment of superficial lesions. This reduces the required voltage from the kilovolt level to the hundred-volt level. The four-electrode method reduced contact resistance interference, and the Nyquist plots showed a unique double-arc pattern. Changes in cell wall resistance correlated with ablation depth ( = 0.86) with a prediction error of <10%. This study presents an innovative approach for IRE therapy that combines low-voltage operation with real-time feedback through impedance spectroscopy, thereby offering improved safety and treatment monitoring.
More Related Videos
Related Concept Videos
Reversible and Irreversible Processes
Role of Communication in the Nursing Process I: Assessment and Diagnosis
The nursing process considers the patient's emotional and physical well-being. The process can be repeated or stopped at any point if judged essential. Assessment is the first step in the nursing...
Voltage
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Nursing Process for Patient and Caregiver Teaching I: Assessment and Diagnosis
It is critical to determine the patient's learning needs during the assessment. Determination of learning needs compounds data...
Self-Efficacy