Related Experiment Video
Updated: Jan 23, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Dosimetric results of whole body irradiation with MOSFET dose tracking to eliminate interfractional variations
Taha Erdoğan1, İbrahim Eker2, Duriye Öztürk3
1Department of Radiation Oncology Faculty of Medicine, Cancer Institute, Afyonkarahisar Health Sciences University, Zafer Health Complex, Dortyol District, Afyonkarahisar, 03030, Turkey. taha.erdogan@afsu.edu.tr.
Abstract:
Total body irradiation (TBI) is an essential component of conditioning regimens prior to hematopoietic stem cell transplantation (HSCT), particularly in paediatric patients. However, achieving dose homogeneity throughout the treatment course remains a major challenge due to large treatment fields, tissue heterogeneity, and inter-fraction variations. The aim of this study was to investigate the feasibility and impact on dose homogeneity of fraction-based adaptive dose modulation supported by dynamically adjusted rice bag compensators, based on real time metal oxide semiconductor field-effect transistor (MOSFET) feedback, using in vivo dosimetry (IVD) in bilateral TBI. In this context, IVD measurements were performed using MOSFET detectors at the brain, neck, lung, umbilical, and pelvic regions during each treatment fraction in patients undergoing bilateral TBI. Based on these measurements, the thickness of the rice-bag compensators was dynamically adjusted between fractions. Calculated dose values were compared with MOSFET measured doses for each anatomical region. Statistical analysis revealed no significant differences between calculated and MOSFET-measured doses across all anatomical regions (p > 0.05), indicating a high level of agreement between planned and delivered doses. The highest dose differences were observed in the lung region (up to 106.9%), whereas the lowest differences were observed in the neck region (up to 100.8%). In conclusion, fraction-based IVD monitoring using MOSFET dosimetry enables adaptive dose modulation in bilateral TBI, reduces inter-fraction dosimetric uncertainties, and provides an effective quality assurance strategy to improve dose homogeneity and treatment safety, particularly in paediatric patients.
Related Concept Videos
Nonlinear Pharmacokinetics: Dependence of Elimination Half-Life and Dose Clearance
A study on guinea pigs examined the...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
MOSFET
In an n-MOSFET, the structure includes n-type source and drain...
MOSFET Amplifiers
Characteristics of MOSFET
Various vital parameters influence their functionality, which is crucial for theory and electronics applications. First, channel dimensions, precisely length, and width, are pivotal. The size of these channels affects the transistor's ability to carry current and switching speeds; shorter channels typically enable...
MOSFET: Depletion Mode
The primary characteristic of depletion-mode MOSFETs is their ability to conduct current between the drain and source terminals without gate bias. This inherent conductivity...