Related Experiment Video
Updated: Jan 24, 2026

Chronic Ovine Model of Right Ventricular Failure and Functional Tricuspid Regurgitation
Published on: March 17, 2023
Changes in Biventricular Cardiac Mechanics After Transcatheter Edge-to-Edge Repair for Severe Tricuspid Regurgitation
Giulio M Mondellini1, Antoon J M van den Enden1, Mark M P van den Dorpel1
1Department of Cardiology, Cardiovascular Institute, Erasmus University Medical Center, Rotterdam, the Netherlands.
Background:
Transcatheter edge-to-edge repair (TEER) is an established therapy for severe tricuspid regurgitation (TR). Invasive pressure-volume (PV) analysis is the gold standard for characterizing ventricular function and ventricular-vascular interactions. The effects of tricuspid TEER on biventricular PV relationships are unknown.
Objectives:
The authors aimed to assess postprocedural changes in right (RV) and left ventricular (LV: 1) end-systolic and end-diastolic pressures and volumes; 2) ventricular-arterial coupling, expressed as end-systolic elastance (Ees) to effective arterial elastance (Ea) ratio; and 3) metabolic demand, represented by PV area (PVA).
Methods:
We used a conductance catheter to determine RV and LV PV relationships before and after tricuspid TEER. Pre- and postprocedural changes in cardiac mechanics were compared using the paired-samples t-test or Wilcoxon signed rank test.
Results:
Among the twenty-two patients (mean age 80 ± 6 years, 46% female, median LV ejection fraction of 52 [IQR 44-55]%) with severe TR, tricuspid TEER resulted in significant TR reduction and lower RV volumes (end-diastolic volume from 114.8 ± 32.2 to 102.0 ± 26.8 mL, P < 0.001). RV afterload increased (Ea: 0.55 [0.47-0.81] mm Hg/mL to 0.85 [0.65-1.27] mm Hg/mL, P < 0.001) as did RV contractility (Ees: from 0.46 [0.33-1.06] to 0.82 [0.55-2.07] mm Hg/mL, P < 0.001), with a stable RV Ees/Ea, preserved stroke volume, RV end-diastolic pressure, PVA, and stroke work-to-PVA ratio. LV end-diastolic volume increased, (108.0 ± 31.8-114.0 ± 32.2 mL, P < 0.001), whereas LV pressures, contractility, Ees/Ea, PVA, and stroke work-to-PVA remained unchanged.
Conclusions:
TR reduction with tricuspid TEER generated immediate RV volume unloading, increased RV afterload, and enhanced RV contractility, maintaining forward stroke volume and increasing LV preload.
More Related Videos
Related Concept Videos
Mismatch Repair
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
Mechanism of Cardiac Arrhythmias
Nucleotide Excision Repair
Overview of DNA Repair
Chemically...
Base Excision Repair
The first step of...