Related Experiment Video
Updated: Jan 24, 2026

Ultrasound Assessment of Flow-Mediated Dilation of the Brachial and Superficial Femoral Arteries in Rats
Published on: November 3, 2016
Computational analysis of blood flowing through an artery with post stenotic dilatation by implying Sisko model
Azad Hussain1, Muhammad Naveel Riaz Dar2, Arosha Iftikhar2
1Department of Mathematics, University of Gujrat, Gujrat, 50700, Pakistan. azad.hussain@uog.edu.pk.
Abstract:
This study looks into the intricate dynamics of blood flow within a blood vessel with both stenosis and dilatation. Unlike previous studies, blood is modeled as a Sisko non-Newtonian fluid, departing from the traditional Newtonian assumption, in order to accurately depict its non-Newtonian behavior. The Sisko model is a flexible tool for hemodynamic research since it is used for a broad variety of arterial circumstances, such as different dilation geometries and degrees of stenosis. To investigate the effects of changing the Sisko fluid properties on blood flow through the vessel, thorough parametric research is carried out by considering various model parameters using the finite element method (FEM). This study mainly focuses on the fluid flow behavior in the post-stenotic dilatation. The influence of stenosis severity, dilatation extent, and flow parameters on hemodynamic features is investigated. The fluid motion is explained by using the governing equations. The modeled governing equations are solved using the finite element method (FEM), which breaks down the artery into smaller computationally manageable elements using a normal mesh. A weak formulation has been derived by multiplying the governing PDEs by appropriate test functions and then integrating over the domain. Appropriate boundary conditions are defined, including no-slip at the artery wall, normal inward velocity, general inward heat flux, and outlet pressure. Numerical simulations are used to examine velocity patterns, shear stress distribution, and pressure drop throughout stenotic and dilated regions. Additionally, variations in temperature and heat transfer are also examined as potential causes of effects on blood flow. The Sisko model's governing equations are shown in cylindrical coordinates. It has been observed that when blood passes through stenosis, its velocity increases and its pressure lowers as a result of greater flow resistance. Also, a small temperature increase occurs from viscous heating in the stenotic area. Further study shows that the parametric variation in the model parameter also affects the hemodynamics of fluid flow. The results are shown graphically in order to better understand the hemodynamics of blood under various parameters. The results aid in the development of cutting-edge diagnostic and treatment approaches and offer insightful information about the pathophysiology of artery illnesses. This study would provide insight into the long-term effects of vascular disease by examining the effects of developing atherosclerosis on hemodynamic parameters and blood flow patterns in the presence of post-stenotic dilatation.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Blood Flow
Parametric Survival Analysis: Weibull and Exponential Methods
Weibull Distribution
The Weibull distribution is a flexible model used in parametric survival analysis. It can handle both increasing and decreasing hazard rates, depending on its shape parameter...
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Analysis Methods of Pharmacokinetic Data: Model and Model-Independent Approaches
The model approach uses mathematical models to describe changes in drug concentration over time. Pharmacokinetic models help characterize drug behavior in patients, predict drug concentration in the body fluids, calculate optimum dosage regimens, and evaluate the risk of toxicity. However, ensuring that the model fits the experimental data accurately...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...