Related Experiment Video
Updated: Jan 24, 2026

Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
Comparison of visual outcomes between bilateral EDOF IOL implantation and combined EDOF and bifocal IOL implantation
Jia-Yan Fang1,2,3, Jing Jin1,2,3, Yi-Ling Jiang1,2,3
1National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, Zhejiang Province, China.
Aim:
To compare the visual outcomes between bilateral implantation of Tecnis ZXR00 extended depth-of-focus (EDOF) intraocular lenses (IOLs) and mixed implantation of Tecnis ZXR00 (EDOF) with Tecnis ZMB00 (bifocal) IOLs.
Methods:
This postoperative cross-sectional study enrolled patients who underwent phacoemulsification combined with IOL implantation. Patients were divided into two groups: the bilateral ZXR00 group (ZXR00-only group) and the mixed IOL group (ZXR00+ZMB00 group). Primary outcome measures included uncorrected and corrected distance visual acuity (UDVA, CDVA), uncorrected and distance-corrected near visual acuity (UNVA, DCNVA), uncorrected and distance-corrected intermediate visual acuity (UIVA, DCIVA), and defocus curves. Secondary outcome measures were visual quality, spectacle independence, patient satisfaction, photic phenomena, and stereopsis.
Results:
A total of 47 patients (94 eyes) were included, with 26 patients (11 males, 15 females) in the ZXR00-only group (mean age: 62.73±7.24y) and 21 patients (7 males, 14 females) in the mixed group (mean age: 65.71±9.16y). There was no statistically significant difference in age between the two groups (P=0.218). The mixed group showed significantly better binocular DCNVA compared to the ZXR00-only group (P=0.002). Defocus curve analysis revealed that the mixed group exhibited superior performance at -2.5 to -4.0 D but inferior performance at -0.5 and -1.5 D. Near stereoacuity was significantly poorer in the mixed group (Randot: 5.589±0.744 vs 6.240±0.394 ln arcsec; Contour: 4.966±0.973 vs 5.740±0.833 ln arcsec; both P<0.01). Both groups achieved high levels of spectacle independence and patient satisfaction, with no significant differences in photic phenomena or questionnaire scores.
Conclusion:
Mixed implantation of EDOF and bifocal IOLs improve near visual acuity but may compromise near stereopsis. This approach provides a viable option for patients prioritizing near vision; however, caution is recommended for individuals requiring fine stereoscopic vision for daily or professional tasks.
More Related Videos
07:00Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
Published on: June 21, 2024
11:22Implantation and Recording of Wireless Electroretinogram and Visual Evoked Potential in Conscious Rats
Published on: June 29, 2016
Related Concept Videos
Predicting Reaction Outcomes
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care...
Evolutionary Relationships through Genome Comparisons