Related Experiment Video
Updated: Jan 24, 2026

Establishment and Validation of a Rat Model of Pulmonary Arterial Hypertension Associated with Pulmonary Fibrosis
Published on: May 23, 2025
A fully automated explainable predictive model for diagnosing pre-capillary and post-capillary pulmonary hypertension
Turki Nasser Alnasser1,2,3, Alireza Hokmabadi1,4, Elliot W Checkley5
1School of Medicine and Population Health, The University of Sheffield, Sheffield S10 2TN, United Kingdom.
Aims:
Unenhanced chest CT is frequently used to assess lung malignancy and parenchymal disease. Harnessing CT data to quantify cardiac and vascular structures has the potential to improve the diagnosis of heart failure and pulmonary hypertension (PH). This study aims to develop a deep learning model to segment and analyse cardiothoracic structures from unenhanced CT images to diagnose PH, pre-capillary PH and PH associated with left heart disease (LHD).
Methods And Results:
A twelve-structure cardiothoracic segmentation model was developed using an institutional cohort (n = 55, 35/9/11 training/validation/testing). Model performance was evaluated using Dice similarity coefficients (DSC). Volumetric measurements were compared to manual values using intra-class correlation (ICC) and visually assessed by four observers using an external cohort (n = 50, from 26 hospitals). Univariable and multivariable regression analyses were performed using a cohort of 368 patients (254/114 training/testing). Receiver-operating characteristic curves were plotted and the area under the curves (AUC) with confidence intervals (CI) were calculated. The model yielded a DSC segmentation performance of ≥0.87 for 9/12 segmented structures and ICC > 0.95 for 10/12 structures. Most of the segmented structures scored as excellent in the external cohort visual assessment. Diagnostic accuracy for predicting PH was high [AUC = 0.88 (CI: 0.80-0.96), sensitivity = 70%, specificity = 100%], including pre-capillary PH [AUC = 0.84 (CI: 0.74-0.94), sensitivity = 72%, specificity = 94%] and PH-LHD [AUC = 0.86 (CI: 0.79-0.93), sensitivity = 94%, specificity = 63%].
Conclusion:
A fully automated model for multi-structure cardiothoracic segmentation on unenhanced CT is achievable. The model can predict PH and identify patients with pre-capillary PH and PH-LHD with promising performance.
Related Concept Videos
Capillary Beds
Capillaries connect arterioles, small branches of arteries, to venules,...
Capillary Exchange
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Capillaries and Their Types
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...