Related Experiment Video
Updated: Jan 24, 2026

Enhanced Rabies Surveillance Using a Direct Rapid Immunohistochemical Test
Published on: April 30, 2019
A portable bilayer microneedle patch for rapid and patient-friendly administration of rabies immunoglobulin and
Yaojun Lu1,2,3, Hanhan Xie4, Ketong Wu5
1National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Guangzhou 510006, China. wanglin3@scut.edu.cn.
Abstract:
Rising global dog ownership increases the risk of rabies, a viral disease with an almost 100% fatality rate. Current post-exposure prophylaxis (PEP) methods involving injections of human rabies immunoglobulin (HRIG) are invasive and painful, resulting in reduced compliance. Furthermore, delays associated with traditional methods can undermine their effectiveness during emergencies, highlighting the need for more efficient alternatives. This study explored microneedle (MN) patches as a less painful and more patient-friendly method for delivering HRIG. We developed a bilayer MN patch composed of a hyaluronic acid (HA) tip containing HRIG and a polyvinylpyrrolidone (PVP) base incorporating tazarotene (TA). The tip dissolved within two minutes, releasing effective doses of HRIG, while the base released TA to promote wound healing. The patch can be stored in blister packaging, maintaining stability without the need for cold-chain storage. Characterization confirmed the patch's biocompatibility and its ability to enhance cell migration in vitro. In vivo testing using a rabies-infected mouse model demonstrated effective prevention of rabies and improved tissue repair following patch application. The patch's portability, stability, and efficacy make it ideal for emergency scenarios, offering reduced discomfort compared to traditional methods. This approach also broadens the potential applications of microneedles in emergency care and vaccination.
More Related Videos
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Long-patch Base Excision Repair
Immunoglobulin-like Cell Adhesion Molecules
Ig-CAMs exhibit either homophilic binding (to other Ig-CAMs) or heterophilic binding (to other ligands such as integrins). While most Ig-CAMs...
Asymmetric Lipid Bilayer
Assembly of the Lipid Bilayer in the ER
A large chunk of any biological membrane is composed of phospholipids. These lipids have a heterogeneous distribution across different subcellular organelles and even between...
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...

