Transcatheter Tricuspid Valve Replacement in Patients With Cardiac Implantable Electronic Device Leads: The TRIPLACE
Bryan P Traynor1, Andrea Scotti2, Rishi Puri3
1Division of Cardiology, Structural Heart Program, St Michael's Hospital, Toronto, Ontario, Canada.
Background:
Patients undergoing orthotopic transcatheter tricuspid valve replacement (TTVR) frequently present with a cardiac implantable electronic device (CIED) lead traversing the tricuspid valve.
Objectives:
This study sought to investigate the clinical, procedural, and lead-related outcomes of orthotopic TTVR in patients with transvalvular CIED leads.
Methods:
All consecutive patients enrolled in the multicenter TRIPLACE (Global Multicenter Registry on Transcatheter Tricuspid Valve Replacement) registry were included for analysis. Patients were stratified based on the presence of a CIED lead traversing the tricuspid valve. Changes in lead function parameters were assessed after TTVR in a subset of these patients who had pacemaker lead parameter data recorded. Lead failure was defined as structural or electrical malfunction requiring new lead or CIED insertion.
Results:
Among 395 patients, 104 (26.3%) had transvalvular CIED leads. Procedural success, symptomatic improvement, and 30-day mortality were comparable between those with and without CIED. Patients with CIED leads had lower rates of mild or less residual tricuspid regurgitation (82.6% vs 91.4%; P < 0.041) and higher rates of moderate or greater paravalvular leak (17.1% vs 7.1%; P < 0.017). Lead failure occurred in 5.8% over a median follow-up time of 183 days, with modest changes in pacing thresholds. No significant increase in adverse events or mortality was observed at 30 days.
Conclusions:
Orthotopic TTVR in patients with transvalvular CIED leads can be safely and effectively performed with low rates of lead failure. Significant paravalvular leak and residual tricuspid regurgitation is more common with a jailed lead. These patients require close CIED follow-up with alternative pacing strategies in place, particularly when pacing dependent. (Global Multicenter Registry on Transcatheter TRIcuspid Valve RePLACEment [TRIPLACE]; NCT06033274).
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Electron Affinity
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Phase-lead and Phase-lag Controllers
Electron Configuration of Multielectron Atoms
Continuous Renal Replacement Therapy