Related Experiment Video
Updated: Jan 24, 2026

A Protocol for Explant Cultures of IDH1-mutant Diffuse Low-grade Gliomas
Published on: May 9, 2025
Differentiation of high-grade glioma and primary central nervous system lymphoma based on imaging heterogeneity
Ming Liu1, Jixian Li2, Caiqiang Xue1
1Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, 266003, China.
Abstract:
To evaluate the diagnostic value of a magnetic resonance imaging (MRI)-based imaging heterogeneity scoring system for differentiating high-grade glioma (HGG) from primary central nervous system lymphoma (PCNSL). This multicenter retrospective study analyzed clinical and preoperative MRI data from 314 pathologically confirmed cases (HGG = 167, PCNSL = 147), comprising 211 patients with single lesions (HGG = 130, PCNSL = 81) and 103 with multifocal lesions (HGG = 37, PCNSL = 66). Patients were randomly assigned to training (single-lesion: n = 147; multifocal: n = 72) and validation (single-lesion: n = 64; multifocal: n = 31) sets in a 7:3 ratio. Distinctive imaging features were used to construct separate logistic regression (LR) models for single-lesion and multifocal-lesion cases, with corresponding scoring systems developed. A baseline model incorporating conventional predictors was developed for comparison. Diagnostic performance was assessed using receiver operating characteristic (ROC) curves (area under the curve [AUC], 95% confidence interval [CI]), Hosmer-Lemeshow tests (goodness-of-fit), calibration curves, and decision curve analysis (DCA). A sensitivity analysis was performed on excluded steroid-treated patients. For single-lesion cases, the training and validation AUCs were 0.940 (95%CI: 0.897-0.983) and 0.908 (0.836-0.981), respectively. Multifocal models achieved training and validation AUCs of 0.960 (0.921-0.999) and 0.927 (0.805-1.000). The heterogeneity scoring system demonstrated significant incremental value over the baseline model (ΔAUC: +0.160-0.290). Hosmer-Lemeshow tests indicated excellent model fit (single-lesion training: χ²= 2.489, P = 0.778; validation: χ² = 6.193, P= 0.185; multifocal training: χ² = 1.760, P = 0.881; validation: χ² = 9.241, P = 0.055). DCA demonstrated substantial net clinical benefit across threshold probabilities. The scoring systems established diagnostic thresholds as follows: ≥ 19 points for HGG (single-lesion) and > 19 points (multifocal), with lower scores indicating PCNSL. Center-stratified validation and repeated cross-validation confirmed strong generalizability across institutions (AUC: 0.934-0.941). The system maintained robust performance in the sensitivity analysis of steroid-treated patients. This MRI heterogeneity-based scoring system provides robust diagnostic accuracy for distinguishing HGG from PCNSL, serving as an objective clinical decision-support tool.
More Related Videos
07:52Multiplexed Fluorescent Immunohistochemical Staining, Imaging, and Analysis in Histological Samples of Lymphoma
Published on: January 9, 2019
07:39Co-culture of Glutamatergic Neurons and Pediatric High-Grade Glioma Cells Into Microfluidic Devices to Assess Electrical Interactions
Published on: November 17, 2021
Related Concept Videos
What is a Nervous System?
Measures of Central Tendency
The Parasympathetic Nervous System
The Sympathetic Nervous System
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
The Central Dogma