Related Experiment Video
Updated: Jan 25, 2026

Author Spotlight: Evaluating the Adjuvant Efficacy and Safety of Angong Niuhuang Pill in Viral Encephalitis Treatment
Published on: April 19, 2024
Editor's Choice - Dynamic Risk of Death following Application of Paclitaxel Coated Devices in the Femoropopliteal
Konstantinos Katsanos1, Stavros Spiliopoulos2, Athanasios Saratzis3
1Division of Interventional Radiology, Patras University Hospital, Rion, Greece.
Objective:
There has been major controversy regarding the long term risk of death associated with the use of paclitaxel coated devices in the lower limbs. The authors performed a contemporary systematic review and meta-analysis.
Data Sources:
Data sources included published literature and repositories of regulatory agencies.
Review Methods:
All cause mortality was analysed on the intention to treat principle. Because of violation of proportional hazards, reconstructed patient level survival data (R2 = 0.999) were fitted with piecewise Cox models and flexible generalised survival models with natural splines and shared frailty terms. Survival differences were summarised with the non-parametric statistical tests of the difference and the ratio of restricted mean survival time lost (RMTL).
Results:
Thirty-four randomised studies with 7 486 subjects and 25 465 person years were included, more than twice the size of the latest industry sponsored meta-analysis for regulatory purposes. In the long term, there were 575 deaths amongst 4 231 patients in the paclitaxel arms (13.6% crude risk) vs. 367 deaths amongst 3 255 patients in the control arms (11.3% crude risk), with an average hazard ratio (HR) of 1.18 (95% confidence interval [CI] 1.03 - 1.35; p = .015). The RMTL ratio (non-parametric analogue of HR) was 1.21 times (95% CI 1.07 - 1.38; p = .003) at 5 years. The absolute RMTL difference was 0.08 years (95% CI 0.03 - 0.13; p = .004) at 5 years. The HR significantly varied over time, displaying a dynamic temporal pattern. Soon after treatment, HR progressively increased and became statistically significantly higher before the end of the first year and for most of the second year (HR 1.45, 95% CI 1.11 - 1.89; p = .007), before declining towards unity (neutral) again up to 5 years. There was modest between trial heterogeneity (θ = 0.083; p = .017) and level of certainty by Grading of Recommendations Assessment, Development and Evaluation was moderate.
Conclusion:
There is a significant, dynamic increase in all cause mortality following application of paclitaxel coated devices in the femoropopliteal artery.
Related Concept Videos
Contemporary Psychology
Biopsychology
Biopsychology, also known as biological psychology or behavioral neuroscience, focuses on the biological underpinnings of behavior and mental processes. It...
Control Systems: Applications
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The...
Statistical Software for Data Analysis and Clinical Trials
Dynamics Of Circular Motion: Applications
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview