Related Experiment Video
Updated: Jan 25, 2026

Systematic Analysis of In Vitro Cell Rolling Using a Multi-well Plate Microfluidic System
Published on: October 16, 2013
Are resorbable plating systems comparable to conventional titanium plating in paediatric maxillofacial trauma
Sibgutulah Rashid1, Vyakhya Akhileshkumar Gupta1, Shivendra Choudhary2
1Department of Dentistry (OMFS), All India Institute of Medical Sciences, Patna, India.
Abstract:
This systematic review and meta-analysis evaluated the effectiveness of resorbable versus titanium plating systems in the management of paediatric maxillofacial fractures. A comprehensive search of PubMed, Embase, Scopus, and specialty journals up to December 2024 identified six retrospective studies published between 2010 and 2024, involving 1,584 patients aged ≤18 years. Both resorbable and titanium systems provided satisfactory fracture stability and healing. Titanium fixation was consistently associated with higher complication rates, ranging from 8%-12% whereas resorbable systems demonstrated rates of 0%-11%, mostly minor complications. Titanium fixation was frequently associated with hardware removal, with reported rates ranging from 15%-95%, reflecting both complication-related and protocol-driven removals, whereas none of the resorbable systems required secondary surgery for hardware removal. Meta-analysis demonstrated a non-significant reduction in complication odds with resorbables compared with titanium (odds ratio 0.42; 95% confidence interval 0.12 to 1.48; p = 0.18; I2 = 52%). These findings indicate that resorbable plating systems offer comparable stability to titanium, with fewer complications and the significant advantage of eliminating the need for removal. Titanium remains the preferred option for load-bearing mandibular fractures due to its superior mechanical strength, while resorbables appear effective for non-load-bearing and growth-sensitive sites. Further prospective trials with long-term follow up are required to confirm their impact on craniofacial growth and cost-effectiveness.
More Related Videos
04:34Meta-Analysis of the Effectiveness and Safety of Shugan Jieyu Capsules for the Treatment of Insomnia
Published on: February 17, 2023
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Comparative Excretory Systems
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Fluid Pressure over Curved Plate of Constant Width
Steady, Laminar Flow Between Parallel Plates
Fluid Pressure over Flat Plate of Constant Width
The resultant force...