Prolonged Smartphone-Based Photoplethysmography for Heart Rhythm Monitoring After Repeat Ablation of Atrial
Dennis Lawin1, Alina Hoffmann1, Thorsten Lawrenz1
1Bielefeld University, Medical School and University Medical Center OWL, Klinikum Bielefeld - Mitte, Department of Cardiology and Intensive Care Medicine, Bielefeld, Germany.
Background & Aim:
Photoplethysmography (PPG) enables mobile health (mHealth) heart rhythm monitoring (HRM). We aimed to assess patient experience and detection rates of arrhythmia recurrence with a mHealth HRM after repeat ablation of atrial fibrillation (AF).
Methods:
Patients undergoing repeat ablation of AF were instructed to perform three rhythm recordings daily using a PPG-based smartphone application over a follow-up (FU) period of 6 months. Compliance was assessed as the number of actual measurements per number of expected measurements. Motivation was calculated as the ratio of the total number of days where the expected measurements were performed to the total number of monitoring days. Arrhythmia recurrence was compared between mHealth and conventional HRM comprising of 12-lead- and Holter-ECGs at 3 and 6 months after ablation.
Results:
A total of 58 patients (37.9% female; median age 66.0 years, interquartile range [IQR] 59.8-72.3) were enrolled and participated in FU. A total of 21,985 PPG recordings have been performed (27.7% symptomatic). The median compliance for performing three measurements per day was 73.8% (IQR 43.8-99.9) and the motivation rate was 33.6% (IQR 12.6-79.8). Freedom from AF/atrial flutter was observed in 58.6% of the patients in the mHealth HRM and 82.8% in the conventional HRM (HR 3.140; 95%CI 1.593-6.188; p=0.0012). Of the PPG measurements indicating AF or atrial flutter, symptoms were reported in only 43.0%.
Conclusions:
Patients undergoing repeat ablation of AF have high compliance for participating in a prolonged mHealth HRM over 6 months. The detection rate of atrial arrhythmia recurrences was higher in the mHealth compared to conventional FU.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Secondary Motives: Power Motivation and Achievement Motivation
Power motivation is characterized by the desire to influence, control, or have an impact on others. It is shaped by an individual's experiences, social environment, and cultural context. People with high power motivation are...
Secondary Motives: Affiliation Motivation and Aggression Motivation
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...