Related Experiment Video
Updated: Jan 25, 2026

06:57
In Vivo Infection with Leishmania amazonensis to Evaluate Parasite Virulence in Mice
Published on: February 20, 2020
8.7K
Correction: Amphotericin B-Loaded Bigel: Characterization and in vivo Antileishmanial Evaluation in BALB/c Mice
Rosilene Ribeiro de Sousa1, Matheus Oliveira do Nascimento2, Leandro Josuel da Costa Santos2
1Graduate Program in Pharmaceutical Sciences, Federal University of Piauí, Teresina, Brazil. rosersena@gmail.com.
AAPS Pharmscitech
|January 23, 2026
Abstract
No abstract available in PubMed .
Related Concept Videos
Distance Corrections
285
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
285
Power Factor Correction
510
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
510
NMR Spectrometers: Resolution and Error Correction
1.0K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.0K
Impact Loading
678
Impact loading occurs when a moving object collides with a stationary structure, such as a rod with a uniform cross-sectional area fixed at one end. Under these conditions, the rod absorbs the kinetic energy from the striking object, leading to deformation and subsequent stress development. As the rod returns to its original position and reaches maximum stress, the absorbed energy, initially manifested as kinetic energy, transforms entirely into strain energy.
In cases of elastic deformation,...
In cases of elastic deformation,...
678
Eccentric Loading
929
Eccentric loading is a crucial concept in the study of structural engineering and mechanics, particularly when analyzing the stability and stress distribution in columns. Unlike centric loading, where the force is applied along the centroidal axis, causing uniform compression, eccentric loading occurs when a force is applied off-center. This off-center application introduces not only direct compressive stress but also bending stress, significantly influencing the column's behavior under...
929
Distributed Loads
958
Distributed loads are a common type of load that engineers and scientists encounter in various practical situations. Distributed loads often refer to a type of load spread over a surface or a structure and can be modeled as continuous force per unit area.
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
958

