Related Experiment Video
Updated: Jan 25, 2026

An Anatomical Study of Nerves at Risk During Minimally Invasive Hallux Valgus Surgery
Published on: February 17, 2018
Intramedullary locking plates device versus headless screw fixation for treatment of hallux valgus deformity: A
Yi-Ping Wei1,2,3,4,5, Yi-Jiun Chou1
1Department of Orthopedics, Kaohsiung Veterans General Hospital, Kaohsiung City, Taiwan.
Abstract:
This retrospective observational study aimed to evaluate the outcomes of subcapital osteotomy using an intramedullary locking plate for the treatment of hallux valgus (HV) deformity. We hypothesized that plate fixation would provide superior angular correction and lower recurrence compared to screw fixation. Between January 2018 and July 2023, a total of 49 feet underwent corrective osteotomy for HV. Of these, 36 feet were treated with headless screws and 13 with intramedullary locking plates. All cases had a minimum follow-up duration of 12 months. Radiographic outcomes were assessed using weight-bearing radiographs obtained preoperatively and at 1, 6, and 12 months postoperatively. The mean follow-up duration was 24.64 ± 14.34 months in the screw group and 18.23 ± 8.47 months in the plate group. HV recurrence was observed in 9 feet - 7 (77.78%) in the screw group and 2 (22.22%) in the plate group (P = 1.000). The findings demonstrate that subcapital osteotomy with an intramedullary locking plate is effective in correcting the intermetatarsal angle, particularly when compared to the use of headless screws in modified Mitchell osteotomy. Furthermore, precise adjustment of the plate tip position allowed for effective correction of significant deviations in the distal metatarsal articular angle. Three cases of loss of reduction were observed in the screw group, while the plate group experienced minimal complications. Longer-term follow-up data are required to provide a more accurate and comprehensive assessment of clinical outcomes.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Observational Studies
There are three types of observational studies – Prospective, retrospective, and cross-sectional.
Prospective Study
Prospective studies, also known as longitudinal or cohort studies, are carried out by collecting future data from groups sharing similar characteristics. One...
Screw: Problem Solving
To evaluate the...
Plastic Deformations
Plastic Deformations
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...