Related Experiment Video
Updated: Jan 28, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Intramedullary Threaded Nail Versus Dorsal Plate and Screw Fixation of Comminuted Metacarpal Shaft Fractures: A
Andrew D Allen1, Alexander D Jeffs1, Yukun Zhang2
1Department of Orthopaedics, The University of North Carolina, Chapel Hill, NC.
Purpose:
Indications are expanding for the use of intramedullary threaded nail (IMTN) fixation in metacarpal fractures. We hypothesized that IMTN fixation would have superior bending stiffness compared to dorsal plate and screw fixation and provide sufficient stability to withstand cyclic loading comparable with early range of motion.
Methods:
Index, long, ring, and small finger metacarpals were harvested from matched pair cadaveric hands. A midshaft 1.75 mm transverse gap was created to simulate a comminuted fracture. Specimens were randomized into two groups for fixation with either a retrograde IMTN or dorsal plate and screws. Specimens underwent three-point bend testing with an Instron. Each specimen was cyclically loaded at 70 N for 2,000 cycles (composite grasp), followed by 120 N for 2,000 cycles (tip pinch). Specimens were then loaded to failure. Outcomes included cycles to failure, bending stiffness, peak load to failure, and location of failure.
Results:
Bending stiffness was significantly greater in the IMTN group compared to the plate group (136.71 ± 24.19 N/mm vs 39.89 ± 14.08 N/mm). Peak load to failure was greater in the plate group, but this difference was not statistically significant (365.33 ± 79.85 N vs 598.11 ± 372.76 N). During the cyclic loading phases, all specimens in the IMTN group completed the 70 N and 120 N loading phases without failure. In the plate group, two of nine specimens progressed to catastrophic failure during the 120 N cyclic loading phase.
Conclusions:
In a comminuted metacarpal shaft fracture model, IMTN fixation had significantly greater bending stiffness and more consistent load to failure characteristics compared to dorsal plate and screw fixation.
Clinical Relevance:
IMTN fixation provided sufficient stability in comminuted metacarpal shaft fractures to withstand cyclic forces consistent with early range of motion, whereas dorsal plate and screw fixation demonstrated more variable results.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Related Concept Videos
Stresses in a Shaft
Applying equilibrium conditions to the QR segment establishes that the internal shearing forces within the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Accessory Structures of the Skin: Nails
The main components of a nail include the following.
Nail Plate: The nail plate is the visible portion of the nail that extends beyond the fingertips or toes. It is a hard, translucent...
Deformation in a Circular Shaft
Transmission Shafts: Problem Solving
Next, use bending moment diagrams for the shaft to...