Cooldown and Ramp Test of a Low-Cryogen, Lightweight, Head-Only 7T MRI Magnet
Anbo Wu1, Justin Ricci1, Minfeng Xu1
1GE HealthCare Technology and Innovation Center, Niskayuna, NY 12309, USA.
Abstract:
A compact 7.0 T MRI system (C7T) has been successfully constructed, cooled down, and ramped (energized) to 7.01 T at GE HealthCare Technology and Innovation Center. The C7T magnet is designed for a B0-field homogeneity of <1.0 ppm over a 26-cm field-of-view, dedicated for MRI brain imaging. The C7T magnet applies a fully closed-loop cryogenic cooling system which condenses only 12 liters of liquid helium at 4.2 K from high pressure helium gas charged at room temperature. The helium is permanently sealed inside the cooling system even after a quench. This newly developed 7.0 T MRI has similar size and stray magnetic field as a clinical whole-body 3.0 T MRI magnet, it can be easily installed in a 3T scanner bay. This C7T MRI system can greatly improve the access to high performance 7T brain imaging for more patients. The cooldown, ramp and quench protection performance of the compact 7T MRI magnet prototype is reported in this paper.
More Related Videos
06:30Endovascular Perforation Model for Subarachnoid Hemorrhage Combined with Magnetic Resonance Imaging MRI
Published on: December 16, 2021
06:42Cryogenic Sample Loading into a Magic Angle Spinning Nuclear Magnetic Resonance Spectrometer that Preserves Cellular Viability
Published on: September 1, 2020
Related Concept Videos
Muscles that Move the Head
The bilateral sternocleidomastoid, or SCM, and the suprahyoid and infrahyoid muscles are significant head flexors. The SCM muscles originate at the sternum and clavicle and attach to the mastoid process of the temporal bone. The SCM contracts bilaterally to bend the head forward, whereas...
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetism
An individual magnetic pole cannot be isolated. No matter how small, every piece of a magnet contains a north pole and a south...