Variability in Intracranial Vessel Diameters and Considerations for Neurovascular Models: A Systematic Review and
Mahmood Mirza1, Katie Kummer2, Jillienne Touchette2
1Medical Affairs, Cerenovus Galway Ireland.
Background:
In vitro experiments are critical for understanding the impact of medical devices and techniques on blood vessels and blood flow. However, their interpretation is often limited by anatomical models' inability to capture the wide range of vessel sizes observed in real-world practice. The current study aims to address this limitation by describing the distribution of vessel diameters in a real-world population.
Methods:
This systematic literature review using the PubMed database analyzed cerebral vessel diameters in patients from 2000 to 2022. The diameter measurements of various vessels within the neurovasculature were extracted. Random-effects meta-analyses were performed to synthesize vessel diameters across studies. Predicted distributions were generated from the meta-analytical results.
Results:
Seventy-six studies were included in the analysis. The M1 segment, internal carotid artery (cervical and communicating segments), A1 segment, V2 segment, V4 segment, and basilar artery had sufficient data for generating predicted distributions of vessel diameters. Predicted mean diameters were as follows: M1 segment, 2.55 ± 0.42 mm (95th interpercentile range [IPR]: 1.71-3.38); internal carotid artery-cervical segment, 4.74 ± 0.64 mm (95th IPR: 3.49-5.99); internal carotid artery-communicating segment, 3.40 ± 0.64 mm (95th IPR: 2.15-4.66); A1 segment, 1.89 ± 0.34 mm (95th IPR: 1.23-2.55); V2 segment, 3.36 ± 0.67 mm (95th IPR: 2.05-4.67); V4 segment, 2.42 ± 0.74 mm (95th IPR: 0.98-3.86); and basilar artery, 2.96 ± 0.52 mm (95th IPR: 1.94-3.97).
Conclusion:
Cerebral vessel diameter measurements can vary substantially due to patient-specific factors and imaging techniques. This literature review highlights the diverse range of vessel sizes observed in different patient populations, emphasizing the need for anatomical models that accurately represent clinical observations.
Related Concept Videos
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Design Consideration
The factor of safety is another key...
Directing Effect of Substituents: meta-Directing Groups