Causes of Visual Loss in Uveitis: A Retrospective Study at a Tertiary Referral Centre

Mohammed Al-Roubaie1, Nicholas Beare2

  • 1Ophthalmology, Northwick Park Hospital, London, GBR.

Cureus
|January 26, 2026
PubMed
Abstract

Related Concept Videos

Tertiary Healthcare System01:21

Tertiary Healthcare System

Specialized care provided over an extended period is called tertiary care. Usually, a primary or secondary care physician will refer a patient to tertiary care. A patient's maximum physical and mental function is restored in tertiary care, which is caused due to the impact of a chronic illness or condition. Tertiary care aims to achieve the highest level of functioning possible while managing chronic illness. For example, a patient who falls and fractures their hip will need secondary care...
2.2K
Nomenclature of Secondary and Tertiary Amines01:12

Nomenclature of Secondary and Tertiary Amines

The secondary and tertiary amines are derivatives of ammonia, where two and three of its hydrogens are replaced by alkyl groups, respectively. Secondary and tertiary amines can be symmetrical with identical alkyl groups attached to the nitrogen atom or unsymmetrical when more than one type of alkyl group is present. The standard nomenclature of secondary and tertiary amines is similar to the names given to the primary amines. They are generally named alkylamines. As depicted in Figure 1, for...
5.1K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
535
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
372
Major Losses in Pipes01:28

Major Losses in Pipes

When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
2.0K
Minor Losses in Pipes01:25

Minor Losses in Pipes

In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
1.9K