Related Experiment Video
Updated: Jan 28, 2026

A Novel Murine Model of Arteriovenous Fistula Failure: The Surgical Procedure in Detail
Published on: February 3, 2016
Comparison of nBCA and Onyx for Embolization of Spinal Dural Arteriovenous Fistulas
Jacob F Baranoski1, Joshua S Catapano1, Caleb Rutledge1
1Department of Neurosurgery, Barrow Neurological Institute St. Joseph's Hospital and Medical Center Phoenix AZ.
Background:
Endovascular embolization can effectively treat spinal dural arteriovenous fistulas (SDAVFs). One factor limiting the success and durability of endovascular treatments is reliably casting and occluding the draining vein. We sought to compare the efficacies of n-butyl-2-cyanoacrylate (nBCA) and Onyx in the treatment of SDAVFs.
Methods:
We retrospectively analyzed patients with SDAVFs treated with endovascular embolization for whether a "durable cure" was achieved, defined as complete obliteration, clinical improvement, and sustained radiologic cure on follow-up. We compared the outcomes of patients treated with Onyx to those treated with nBCA.
Results:
A total of 40 embolizations for SDAVFs were performed in 38 patients. All patients were treated exclusively with liquid embolysates: Onyx alone (n = 22), nBCA alone (n = 16), or nBCA and Onyx combined (n = 2). For 45% (10/22) of patients treated with Onyx only, complete obliteration of the fistula with casting of the vein was not achieved. These patients were referred for microsurgical ligation. For all 16 patients treated with nBCA only, complete obliteration of the fistula was achieved. All 16 patients exhibited a durable cure compared with 11 of 22 patients (50%) in the Onyx-only group (P = 0.002).
Conclusion:
nBCA may be superior to Onyx for the embolization of SDAVFs. nBCA embolization is safe and effective for a subset of SDAVFs. Prospective studies comparing SDAVF treatment strategies are warranted.
Related Concept Videos
Pulmonary Embolism I: Introduction
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits