Related Experiment Video
Updated: Jan 28, 2026

A Nanobar-Supported Lipid Bilayer System for the Study of Membrane Curvature Sensing Proteins in vitro
Published on: November 30, 2022
Effect of Lubricant Viscosity on Separated Instrument Retrieval Time and Dentine Preservation in Root Canal
Pooya Saeedi1, Maryam Forghani2, Siavash Moushekhian2
1Private Practice, Mashhad, Iran.
None:
This study aimed to evaluate the effect of silicone oils with varying viscosities (100, 350 and 1000 cSt) and 17% Ethylenediaminetetraacetic acid (EDTA) (1.8 cSt) on the efficiency of removing separated instruments using an ultrasonic device from the curved regions of mesio-buccal canals in mandibular first and second molars. Forty-eight mesio-buccal canals of mandibular first and second molars with curvatures ranging from 15 to 30 degrees were prepared and simulated with separated instruments. Nickel-titanium (Ni-Ti) 25-4% rotary files, measuring 3-4 mm in length, were intentionally fractured within the curvature region of the canals. The samples were randomly divided into four groups (n = 12) based on the lubricant used: EDTA and silicone oils with viscosities of 100, 350 and 1000 cSt at 25°C. Primary outcomes were retrieval time and dentine loss from the canal's inner wall, measured via Cone Beam Computed Tomography (CBCT). Secondary outcomes included the coronal exposure of separated instruments to initiate bodily movement and the accuracy of CBCT versus periapical radiography in measuring fractured file length. Data were analysed using the Shapiro-Wilk test for normality, one-way ANOVA and the Kruskal-Wallis test at a significance level of 0.05. The experimental conditions were homogeneous between groups, with no significant differences in canal curvature (p = 0.907), ultrasonic preparation time (p = 0.632), or actual SI length (p = 0.082). The results showed no significant differences among the groups regarding SI retrieval time (p = 0.797), dentine loss (p = 0.653), or coronal SI exposure (p = 0.653). CBCT measurements demonstrated significantly greater accuracy in determining fractured file length compared to periapical radiography (p < 0.001). Within the limitations of this in vitro study, the findings suggest that silicone oils, regardless of their viscosity, did not provide additional benefits over EDTA in reducing retrieval time or preserving dentine in the mesio-buccal canals of mandibular molars. However, CBCT proved more accurate than periapical radiography in measuring SI length. Despite the lack of significant effects of silicone oils with higher viscosity, EDTA remains clinically preferred due to its inherent chelating properties. Further research is needed to confirm or refute these findings.
Related Concept Videos
Space-Time Curvature and the General Theory of Relativity
This has been verified in many experiments. However, space and time are no longer absolute. Two observers moving relative to one another do not agree on the length of objects or the passage of time. The mechanics of objects based on Newton's laws of...
Degree of Curvature and Radius of Curvature
Viscosity
The SI unit of viscosity is...
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Viscosity of Fluid
Retrieval
Recall involves accessing information without cues, such as during an essay test, where individuals must retrieve facts and concepts from memory unaided. Another example is remembering the name of a colleague...