Accuracy of a Novel Desktop Micro-CT Scanner for Direct Digitization of Dental Impressions: A Comparative In Vitro
Jiaying Gu1,2, Liqing Zhu2,3, Wenyue Yang1,2
1Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, Shanghai 200011, China.
None:
Background/Objectives: This study aimed to evaluate the clinical feasibility of a novel desktop micro-computed tomography (micro-CT) scanner for digital impressions through comprehensively assessing its dimensional trueness and morphological accuracy in comparison with other optical-based scanners. Methods: A modified reference model was used to create ten silicone impressions and corresponding plaster models. Four digitization protocols were evaluated: (1) direct scanning of impressions via micro-CT scanner (MCTI), (2) extraoral scanning of impressions via F8 scanner (F8I), (3) extraoral scanning of plaster models via F8 scanner (F8PM), and (4) intraoral scanning of plaster models using Trios 5 scanner (IOSPM). Dimensional trueness was quantified via six linear measurements, and morphological accuracy (trueness and precision) was assessed by 3D surface deviation analysis. Results: Statistically significant differences in linear measurements between the digital impressions and the reference model were observed (p < 0.05). MCTI, F8PM and IOSPM demonstrated higher dimensional trueness than F8I. Although all methods showed high morphological precision, F8I (398.5 ± 43.0 µm) exhibited significantly greater root mean square (RMS) deviations for morphological trueness than MCTI (114.8 ± 42.2 µm), F8PM (142.1 ± 27.7 µm) and IOSPM (134.6 ± 12.0 µm) (p < 0.01). MCTI also demonstrated the highest reliability for morphological trueness according to relative standard deviation (RSD) analysis, with RSD values of 30.83% for MCTI, 41.80% for F8I, 37.26% for F8PM, and 42.55% for IOSPM. Conclusions: The novel micro-CT scanner enables accurate and reliable direct digitization of dental impressions. Its performance is comparable to scanning plaster models with high-end scanners and significantly superior to direct optical scanning of impressions, making it a promising alternative in digital dental workflow.
Related Concept Videos
First Impression
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Uncertainty in Measurement: Accuracy and Precision
Managing Impressions
Improving Translational Accuracy