Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Subcapital Femoral Neck Fracture Despite Cement-Augmented Cephalomedullary Nail Fixation for an Osteoporotic
Suguru Yokoo1, Yukimasa Okada1, Kyotaro Ohno2
1Department of Orthopaedic Surgery, Fukuyama City Hospital, Hiroshima 721-8511, Japan.
Abstract:
Background/Objectives: Cement augmentation of cephalomedullary head elements can improve the purchase of osteoporotic bone; however, it does not eliminate the need for accurate implant positioning or the preservation of sliding. We report the case of an 87-year-old woman who underwent intramedullary nailing with a cement-augmented helical blade for intertrochanteric fracture. Methods: This is a single-patient case report. Calibrated radiographic measurements-tip-apex distance (TAD), calcar-referenced TAD (CalTAD), neck-shaft angle (NSA), and telescoping-were obtained immediately postoperatively and at 4, 7, 12, and 15 months. CT was performed at postoperative week 1 and at failure, and MRI was performed for clinical deterioration. In addition, a targeted narrative review summarizes the evidence on the head-element position, sliding behavior, reduction alignment, and augmentation. Results: Immediate postoperative indices were within the accepted targets: TAD 22.6 mm, CalTAD 22.8 mm, NSA 134°, with the head element inferior on the anteroposterior view and central on the lateral view. Rehabilitation proceeded with full weight bearing as tolerated. Early telescoping was minimal (3.8-3.9 mm). Between 7 and 15 months, progressive varus with shortening of TAD/CalTAD and little additional telescoping was observed, radiographically consistent with relative proximal migration of the head-cement complex and a cleavage plane along the inferior cement mantle, culminating in a subcapital femoral neck fracture with the implant in situ. Emphasis should be placed on accurate implant positioning and preservation of sliding capacity, because cement augmentation alone may not prevent mechanical failure when the implant position or load transfer is suboptimal. Conclusions: Cement augmentation stiffens the interface and reduces micromotion but does not neutralize malposition-induced stresses. Accurate positioning, preservation of sliding, and timely conversion when sliding fails to progress are advisable; these findings are hypothesis-generating from a single case. We propose a position- and sliding-based decision guide to support clinical decision-making; its usefulness remains to be validated in larger studies.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Hydration of Cement
Soundness of Cement
Portland Cement
Fineness of Cement
Direct...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...