Related Experiment Video
Updated: Jan 28, 2026

Detection of Detergent-sensitive Interactions Between Membrane Proteins
Published on: March 7, 2018
Characterization of the Regenerative Capacity of Membranes in the Presence of Fouling by Microalgae Using Detergents
Volker Bächle1, Marco Gleiß1, Hermann Nirschl1
1Institute of Mechanical Process Engineering and Mechanics (MVM), Karlsruhe Institute of Technology (KIT), Strasse am Forum 8, 76131 Karlsruhe, Germany.
Abstract:
The filtration of microalgae generates fouling through algal matter and exopolymer particles with consequences for the flow rate. Therefore, regeneration that is as complete and continuous as possible is necessary. For this purpose, a commercial membrane with a pore size of 0.8 µm is contaminated with the microalgae mixture Haematoccocus Pluvialis and Tetradesmus obliquus, and then regenerated with mechanical (backwashing), chemical (HCl, NaOH, NaClO, P3-Ultrasil) and biological (dishwashing and laundry detergents) cleaning methods. The filtration time of the individual experiments is compared with a new membrane, and the increase is determined. Backwashing cleans the pores, but the biofilm sticks to the membrane surface and blocks the pores shortly after a new cycle. It was shown that the biofilm can only be removed chemically through oxidative effects or anionic surfactants. Hydrolysis does not remove the biofilm, and it can actually make the blockage worse. Bigger cellular residues can only be removed with enzymes. This improves cleaning performance by 61% compared to commercial cleaning agents for membranes and 42% compared to backwashing.
More Related Videos
10:43Expression, Detergent Solubilization, and Purification of a Membrane Transporter, the MexB Multidrug Resistance Protein
Published on: December 3, 2010
06:12Stab Wound Injury Model of the Adult Optic Tectum Using Zebrafish and Medaka for the Comparative Analysis of Regenerative Capacity
Published on: February 10, 2022
Related Concept Videos
Detergent Purification of Membrane Proteins
Lung Capacity
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Heat Capacity: Problem-Solving
Determine the type of gas: The heat capacity of a gas depends on its molecular structure and the degree of freedom of its molecules. Different types of...
Respiratory Volumes and Capacities I
Respiratory Volumes and Capacities