Related Experiment Video
Updated: Jan 28, 2026

A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
Calibrated Transformer Fusion for Dual-View Low-Energy CESM Classification
Ahmed A H Alkurdi1,2, Amira Bibo Sallow1
1Department of Information Technology, Technical College of Duhok, Duhok Polytechnic University, Duhok 42001, Iraq.
None:
Contrast-enhanced spectral mammography (CESM) provides low-energy images acquired in standard craniocaudal (CC) and mediolateral oblique (MLO) views, and clinical interpretation relies on integrating both views. This study proposes a dual-view classification framework that combines deep CNN feature extraction with transformer-based fusion for breast-side classification using low-energy (DM) images from CESM acquisitions (Normal vs. Tumorous; benign and malignant merged). The evaluation was conducted using 5-fold stratified group cross-validation with patient-level grouping to prevent leakage across folds. The final configuration (Model E) integrates dual-backbone feature extraction, transformer fusion, MC-dropout inference for uncertainty estimation, and post hoc logistic calibration. Across the five held-out test folds, Model E achieved a mean accuracy of 96.88% ± 2.39% and a mean F1-score of 97.68% ± 1.66%. The mean ROC-AUC and PR-AUC were 0.9915 ± 0.0098 and 0.9968 ± 0.0029, respectively. Probability quality was supported by a mean Brier score of 0.0236 ± 0.0145 and a mean expected calibration error (ECE) of 0.0334 ± 0.0171. An ablation study (Models A-E) was also reported to quantify the incremental contribution of dual-view input, transformer fusion, and uncertainty calibration. Within the limits of this retrospective single-center setting, these results suggest that dual-view transformer fusion can provide strong discrimination while also producing calibrated probabilities and uncertainty outputs that are relevant for decision support.
More Related Videos
Related Concept Videos
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
What is Energy?
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Energy Basics
Internal Energy

