Related Experiment Video
Updated: Jan 28, 2026

Brain State-dependent Brain Stimulation with Real-time Electroencephalography-Triggered Transcranial Magnetic Stimulation
Published on: August 20, 2019
Real-time digital hardware trigger system for the Central Detector of the Taishan Antineutrino Observatory
Yuanda Wang1,2, Ping Cao1,3, Yu Zhu1,3
1State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China.
Abstract:
The Taishan Antineutrino Observatory (TAO) is a high-energy resolution reactor antineutrino experiment designed to measure the fine structure of the reactor antineutrino energy spectrum. It employs silicon photomultipliers (SiPMs) to detect photons produced by secondary particles from antineutrino interactions in a gadolinium-doped liquid scintillator. The physics event rate of the TAO is ∼520 Hz. However, the use of 4024 SiPM arrays results in a high dark noise event rate, leading to a total event rate of up to 1 GHz. This presents a significant challenge in the trigger system design: how to accurately and efficiently select rare effective physics events in real-time amidst a vast amount of noise. This paper introduces a fully digital hardware trigger system. The system features a flexible, reconfigurable two-level processing architecture, combined with a real-time triggering algorithm based on the multiplicity trigger criterion. The trigger system has been tested with the simulation data, and a preliminary joint test with the detector system has been completed. The results of the simulation test with a single module suggest that the trigger system can accurately extract the 1 kHz simulation physics events from the substantial amount of dark noise and upload the triggered data to the DAQ system. Besides, in the preliminary joint test, the trigger system accurately extract the given effective physics event data while compressing the hit rate of dark noise from 2 MHz to 500 Hz. The trigger system has been successfully installed and deployed at the TAO experimental site. It has undergone integrated debugging with the full-scale detector and Front-End Electronics (FEC), and preliminary data acquisition tests have been completed. The design objectives of the triggering system have been fulfilled, demonstrating its correctness and reliability in practical application scenarios.
More Related Videos
06:03Author Spotlight: Advancing Real-Time cAMP Detection in Cells Using cADDis Biosensor
Published on: March 22, 2024
08:13SwarmSight: Real-time Tracking of Insect Antenna Movements and Proboscis Extension Reflex Using a Common Preparation and Conventional Hardware
Published on: December 25, 2017
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
The Central Dogma
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
GIS Software, Hardware, and Sources of GIS Data