Related Experiment Video
Updated: Jan 28, 2026

Non-invasive Assessments of Subjective and Objective Recovery Characteristics Following an Exhaustive Jump Protocol
Published on: June 8, 2017
Reliability of the Output Sports Inertial Measurement Unit in Measuring a Reactive Strength Index from the Drop Jump
Conor P Clancy1,2,3, Kieran D Collins2,3, Thomas M Comyns1,4,5
1Department of Physical Education and Sport Sciences, University of Limerick, V94 T9PX Limerick, Ireland.
The Output Sports inertial measurement unit (IMU) reliably measures reactive strength index (RSI) using the Drop Jump (DJ) and 10-5 rebound jump test (10-5 RJT). However, it is not sensitive enough to detect the smallest worthwhile change in RSI.
Area of Science:
- Sports Science
- Biomechanics
- Human Movement
Background:
- The reactive strength index (RSI) is a crucial metric for assessing athletic performance.
- Accurate measurement tools are essential for monitoring RSI changes and training adaptations.
- Inertial measurement units (IMUs) offer a portable solution for quantifying jump performance.
Purpose of the Study:
- To evaluate the trial-to-trial reliability of the Output Sports IMU for measuring RSI.
- To assess the usefulness of the IMU in detecting meaningful changes in RSI.
- To determine if the IMU can detect the smallest worthwhile change (SWC) in RSI.
Main Methods:
- Twenty-three elite male hurlers performed familiarisation and testing sessions of the Drop Jump (DJ) and 10-5 rebound jump test (10-5 RJT).
- The Output Sports IMU was used to measure RSI during these tests.
- Reliability was assessed using intraclass correlation (ICC) and coefficient of variation (CV).
- Usefulness was determined by comparing typical error (TE) with the smallest worthwhile change (SWC).
Main Results:
- The Output Sports IMU demonstrated high reliability for measuring RSI in both DJ and 10-5 RJT (CV ≤ 10%, ICC ≥ 0.8).
- The typical error (TE) for DJ and 10-5 RJT was 0.09 and 0.08, respectively.
- Both tests, using the IMU, were rated as 'marginal' for detecting the SWC but 'good' for detecting moderate changes in RSI.
Conclusions:
- The Output Sports IMU is a reliable tool for measuring RSI in elite athletes using the DJ and 10-5 RJT.
- The current sensitivity of the IMU is insufficient to detect the smallest worthwhile change in RSI.
- Further research is needed to validate the Output Sports IMU's RSI measurements against criterion methods.