Clinically relevant effective dose k-factors for brain CT derived from Korean body size phantoms and National CT Dose
Izzati Lia Wilda1, Ajin Jo2, Yeji Kim1
1Department of Multidisciplinary Radiological Science, The Graduate School of Dongseo University, Busan, Republic of Korea.
Abstract:
The global increase in computed tomography (CT) use, highlighted by a 40% growth in South Korea over the past decade, has made CT a significant source of medical radiation exposure, emphasizing the need for accurate effective dose (ED) estimation. This study aimed to develop population-specific effective dose conversion factors (k-factors) for brain CT examinations across the range of tube voltages used in Korean hospitals. Clinical dose parameters were obtained from the Korean National CT Dose Index Registry (KNCTDIR), which compiles large-scale dose-length product (DLP) data from 45 hospitals nationwide. The mean, maximum, and minimum kVp and DLP values were selected to represent typical clinical variations. Monte Carlo simulations were performed using GATE version 10.0b8 with Korean-sized XCAT phantoms for adult and pediatric groups. Organ and effective doses were calculated following ICRP 103 tissue-weighting factors, and k-factors were derived for each age, sex, and voltage condition. The results showed consistent k-factors across the evaluated voltage range, with only minimal sex-related differences. Infants had the highest coefficients (0.0029 mSv/mGy·cm), while pediatric k-factors were lower and remained relatively stable from ages 2 to 15 years. Comparisons with previous Korean and international studies revealed notable quantitative differences, emphasizing the need for updated, population-specific coefficients. The revised k-factors facilitate practical and consistent effective-dose estimation in Korean brain CT procedures.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Dose-Response Relationship: Overview
Drug Dosing: Infants and Children