Related Experiment Video
Updated: Jan 29, 2026

Intraoperative Assessment of Resection Margins in Oral Cavity Cancer: This is the Way
Published on: May 10, 2021
Intraoperative Spectroscopic and Mass Spectrometric Assessment of Glioma Margins: A Systematic Review and
Tomasz Tykocki1, Łukasz Rakasz1
1Department of Paediatric Neurosurgery, Children's Hospital Named After Prof. Dr. Med. Jan Bogdanowicz, 03-924 Warsaw, Poland.
Background:
Maximal safe resection remains a central determinant of outcomes in glioma surgery, yet intraoperative discrimination between tumor and normal brain tissue is limited by the speed and subjectivity of frozen-section analysis. Label-free techniques such as Raman spectroscopy, mass spectrometry (MS), and optical coherence tomography (OCT) offer real-time biochemical and structural characterization that may enhance surgical precision. Their comparative diagnostic accuracy across clinically relevant endpoints has not been comprehensively evaluated.
Methods:
Following PRISMA 2020 guidelines, a systematic review and quantitative meta-analysis were conducted using PubMed, Embase, Scopus, and Web of Science through December 2024. Original human studies evaluating Raman, MS, or OCT for intraoperative glioma margin assessment were included. Pooled sensitivity, specificity, and diagnostic odds ratios (DORs) were calculated using a random-effects model. Subgroup analyses addressed tumor versus normal brain tissue, infiltrated versus non-infiltrated margins, and IDH-mutant versus wild-type gliomas.
Results:
Twenty-four studies comprising 1768 patients met the inclusion criteria. Across all modalities, pooled sensitivity and specificity were 0.89 (95% CI 0.86-0.92) and 0.88 (95% CI 0.84-0.91), with a pooled DOR of 65.7 (95% CI 42.3-101.8; logDOR 4.18), indicating high overall discriminative performance. Tumor versus normal differentiation achieved DOR 72.4 (logDOR 4.28; I2 = 26%), infiltrated margin detection DOR 41.8 (logDOR 3.73; I2 = 41%), and IDH classification DOR 52.3 (logDOR 3.96; I2 = 29%). No publication bias was observed. Raman and MS outperformed OCT.
Conclusions:
Raman spectroscopy, mass spectrometry, and OCT demonstrate strong diagnostic accuracy for real-time intraoperative glioma evaluation, enabling reliable tissue differentiation and molecular profiling that may enhance resection extent and support precision, molecularly informed neurosurgery.
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Margin of Error
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Random and Systematic Errors
Directing Effect of Substituents: meta-Directing Groups