Published on: November 4, 2021
Local Diagnostic Reference Levels for Intracranial Aneurysm Coil-Only Embolization Using a Low-Dose Technique
Mariusz Sowa1, Joanna Sowa2, Kamil Węglarz1
1Department of Neurosurgery, Collegium Medicum University of Warmia and Mazury Aleja Warszawska 30, 10-082 Olsztyn, Poland.
Abstract:
Background/Objectives: Optimizing routine neurointerventional workflow and minimizing exposure to ionizing radiation during coil-only endovascular treatment of intracranial aneurysms depend on operator experience, reduced frame rates during both fluoroscopy and digital subtraction angiography (DSA), and the use of advanced angiographic systems. The low-dose protocol implemented in this study used the lowest available fluoroscopy frame rate (3.125 frames per second [fps]) and a nominal acquisition rate of 2 fps (actual = 2.45 fps) for DSA, three-dimensional (3D) rotational angiography, two-dimensional (2D)/3D mapping, and roadmapping. Methods: This retrospective analysis encompassed 245 coil-only procedures performed at a single tertiary center from 2018 to 2024. Data collected for each procedure included dose-area product (DAP), reference air kerma (Ka,r), fluoroscopy time (FT), and the total number of DSA frames. Local diagnostic reference levels (DRLs; 75th percentile [P75]) and typical values (50th percentile [P50]) were determined and descriptively compared with values reported in the literature. Results: The P75 values, representing DRLs, were 22.4 Gy·cm2 for DAP (literature range, 123-272.8 Gy·cm2), 268 mGy for Ka,r (1171-4240 mGy), 18 min 56 s for FT, and 285 DSA frames. The P50 values were 13.8 Gy·cm2 for DAP (78.7-179.0 Gy·cm2), 196 mGy for Ka,r (801-2804 mGy), 13 min 25 s for FT, and 208 DSA frames. Conclusions: In this single-center cohort, dose metrics for coil-only intracranial aneurysm treatment were within the lower range of published values. Cross-study comparisons are descriptive and require cautious interpretation. The proposed local DRLs may support quality assurance, dose optimization, and patient safety in comparable clinical settings. Further multi-center and multi-operator studies are warranted to evaluate transferability and applicability beyond coil-only procedures.
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Pulmonary Embolism I: Introduction
Inertial Frames of Reference
Non-inertial Frames of Reference
Aneurysm I: Introduction