Clinical Impact of Macrotroponin on Immunometric Troponin Assays: A Cross-Analytical Case Evaluation
Michela Salvatici1, Chiara Corrado1, Rita Passerini2
1UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20138 Milan, Italy.
High-sensitivity cardiac troponin assays are susceptible to analytical interferences, including macrotroponin, an immunoglobulin-bound complex that may cause persistent, non-dynamic, and assay-dependent elevations. This paper describes the case of a 74-year-old woman with hypertension who presented with intermittent mild chest discomfort and exertional dyspnea and exhibited persistently elevated but stable cardiac troponin I concentrations over several months, in the absence of clinical, electrocardiographic, or imaging evidence of myocardial injury. Orthogonal testing revealed discordant results across different assay platforms, and polyethylene-glycol (PEG) precipitation resulted in a substantial signal reduction, confirming macrotroponin as the source of assay-dependent analytical interference. Recognizing this phenomenon is crucial to avoid misdiagnosis, unnecessary diagnostic procedures and inappropriate management in patients with isolated troponin elevation. In conclusion, this report provides evidence-based recommendations on the optimal diagnostic strategies and laboratory approaches to adopt in cases of suspected macrotroponin-mediated interference in high-sensitivity cardiac troponin assays.
High-sensitivity cardiac troponin assays are susceptible to analytical interferences, including macrotroponin, an immunoglobulin-bound complex that may cause persistent, non-dynamic, and assay-dependent elevations. This paper describes the case of a 74-year-old woman with hypertension who presented with intermittent mild chest discomfort and exertional dyspnea and exhibited persistently elevated but stable cardiac troponin I concentrations over several months, in the absence of clinical, electrocardiographic, or imaging evidence of myocardial injury. Orthogonal testing revealed discordant results across different assay platforms, and polyethylene-glycol (PEG) precipitation resulted in a substantial signal reduction, confirming macrotroponin as the source of assay-dependent analytical interference. Recognizing this phenomenon is crucial to avoid misdiagnosis, unnecessary diagnostic procedures and inappropriate management in patients with isolated troponin elevation. In conclusion, this report provides evidence-based recommendations on the optimal diagnostic strategies and laboratory approaches to adopt in cases of suspected macrotroponin-mediated interference in high-sensitivity cardiac troponin assays.
More Related Videos
Related Concept Videos
Crossing Over
The homologous pairs of sister chromosomes—one from the maternal and one from the paternal genome—then begin to align alongside each other lengthwise, matching corresponding DNA positions in a process...
Crossing Over
Monohybrid Crosses
Cross-Sectional Research
Dihybrid Crosses
Impact of Groups on Groups


