Related Experiment Video
Updated: Jan 29, 2026

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Three-Dimensional Combustion Field Temperature Measurement Based on Planar Array Sensors
Xiaodong Huang1, Zhiling Li1, Jia Wang2
1Department of Intelligent and Information Engineering, Taiyuan University, Taiyuan 030051, China.
Abstract:
High-resolution three-dimensional temperature fields are essential for studying flame combustion, and tunable diode laser absorption tomography (TDLAT) is an effective method for diagnosing flame combustion conditions. In actual combustion measurements, the reliance of TDLAT on line-of-sight (LOS) measurements leads to limited data and reduced dimensionality in analyzing combustion fields. This study proposes a method using area-array sensor-coupled absorption spectroscopy to measure the three-dimensional temperature field of flame accurately, aiming for enhanced combustion diagnosis. The laser beam is configured into a cone shape, and after traversing the combustion field under examination, the area-array sensor receives a projection signal. This signal is then used to reconstruct a high-resolution, multidimensional temperature field. We confirmed the accuracy and robustness of the algorithm through numerical simulations and compared these with experimental results from the TDLAT setup. Our TDLAT detection system demonstrates high precision and effectively measures temperature fields in complex flame imaging scenarios.
More Related Videos
10:49Planar and Three-Dimensional Printing of Conductive Inks
Published on: December 9, 2011
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
Related Concept Videos
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Combustion Energy: A Measure of Stability in Alkanes and Cycloalkanes
Alkanes undergo combustion in the presence of excess oxygen and high-temperature conditions to give carbon dioxide and water. A combustion reaction is the energy source in natural gas, liquified...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Internal Combustion Engine
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...