Peak Lactate Within 24 h and Mortality in Septic Shock Patients Receiving Continuous Renal Replacement Therapy: A

Wei-Hung Chang1, Ting-Yu Hu1,2, Li-Kuo Kuo1

  • 1Department of Critical Care Medicine, MacKay Memorial Hospital, Taipei 10449, Taiwan.

Life (Basel, Switzerland)
|January 28, 2026
PubMed
Abstract

Related Concept Videos

Continuous Renal Replacement Therapy01:30

Continuous Renal Replacement Therapy

Continuous Renal Replacement Therapy, also known as CRRT, is a procedural treatment for acute kidney injury (AKI) that gradually removes uremic toxins and fluids while maintaining acid-base balance and stabilizing electrolytes. It is particularly useful for hemodynamically unstable patients. Unlike intermittent hemodialysis, which is faster, CRRT provides a gentler approach over 24 hours, closely mimicking the function of natural kidneys. However, CRRT is not ideal for patients with...
973
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy01:26

Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy

Continuous Renal Replacement Therapy (CRRT) is an essential intervention for patients experiencing severe kidney dysfunction. This therapy offers a continuous mechanism for removing fluids and toxins from the bloodstream, leveraging the patient’s blood pressure to facilitate filtration through a specialized filter. This method contrasts with intermittent dialysis, providing a gentler and more consistent removal of waste products and excess fluid, which is particularly beneficial in...
205
Shock Waves01:16

Shock Waves

While deriving the Doppler formula for the observed frequency of a sound wave, it is assumed that the speed of sound in the medium is greater than the source's speed through it. When this condition is breached, a shock wave occurs.
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
2.5K
Receiver Operating Characteristic Plot01:15

Receiver Operating Characteristic Plot

A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...
484
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations01:08

IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations

Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single...
1.8K
Holter Monitor: 24-Hour Monitoring01:23

Holter Monitor: 24-Hour Monitoring

Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
2.4K